Increased Detectability of Alzheimer Plaques at 7T vs. 3T using High Resolution bSSFP
نویسندگان
چکیده
Introduction: β-amyloid plaques are thought to have an important role in the development and progression of Alzheimer’s disease (AD). Amyloid plaques are detectable at high-field as small hypointense regions in animal models [1] and ex vivo in human specimens [2], though in the latter case, clear separation of plaques from blood vessels remains an ongoing challenge. The underlying cause of the signal change is unknown, although the iron that is known to co-localize with β-amyloid plaques is suspected. Iron sensitivity is theoretically improved at high field strengths [3]. To investigate the relationship between plaque conspicuity and field strength, we imaged human AD brain specimens at 3T and 7T, and compared experimental measurements of signal-to-noise ratio (SNR), contrast, and contrast-to-noise ratio (CNR) to theoretical predictions of SNR. Methods: Based on previously demonstrated advantages of 3T high-resolution balanced steady state free precession (bSSFP) imaging for detecting iron-loaded cells in mouse brain [4], we evaluated this methodology for direct detection of β-amyloid plaques in human AD specimens. We designed simulations and experiments to predict image quality and test the hypothesis that plaque detection would be enhanced at 7T compared to 3T. For purposes of theoretical simulations of SNR, we measured T1 and T2 in white and grey matter from a single formalin-fixed AD brain specimen, at 3T and 7T. For T1 measurement, we used an inversion-prepared fast spin echo sequence, repeated 8 times with different inversion times (TI=50-4000). For T2 measurement, a spin echo sequence was repeated 6 times with different echo times (TE=8-150). These calculated T1s and T2s were used along with other sequence parameters in the bSSFP signal equation to estimate the relative SNR benefit of scanning at 7T compared to 3T. Five AD and five normal formalin-fixed human brain specimens were obtained. Each specimen consisted of five 3cm square slabs that were 4mm in thickness through the frontal, parietal, medial temporal, temporal, and occipital lobes. These were immersed in Fluorinert (3M, USA) in a 4cm diameter sealed container, and scanned with size-matched transmit/receive solenoid coils at 3T and at 7T using a modified bSSFP sequence (TR 21, TE 10.5, FA 20, 8 phase cycles, 0.1mm isotropic voxels, FOV 3cm, 256 0.1mm slices, BW 9kHz for 3T and 8kHz for 7T, total scan time 3h38m for 3T and 3h35m for 7T. Image analysis was performed with MRIcro, Microsoft Excel, and MATLAB. SNR was computed by ROI selection of gray matter/hippocampus/white matter/background from matched AD image slices at 3T and 7T. To quantify presumed plaque contrast, approximately 20 focal signal voids were identified in each specimen on the 7T images and corresponding voids were found on matched 3T images. Presumed plaque contrast (ΔS/S) was computed as the difference between minimal presumed plaque SI and mean SI of surrounding gray matter in the same slab, divided by this surrounding gray matter mean SI. Contrast-to-noise ratio was defined as the product of ΔS/S and SNR. Results: Table 1 reports that T1s increased by roughly 70% in moving from 3T to 7T, while T2s decrease by 10-30%. Subsequent predictions of 7T bSSFP SNR are 79-92% higher than that at 3T, depending on the tissue type. Table 2 reports the predicted and measured SNR, as well as the measured contrast and CNR, for hippocampal tissue. Predicted and measured HC SNR were 79% and 70% higher at 7T compared to 3T, respectively. Importantly, presumed plaque CNR was approximately 3 times higher at 7T compared to 3T, which reflects the combined effects of increased SNR and plaque contrast, and this is emphasized in Figure 2. Figure 1 demonstrates the visual appearance of presumed plaques in a single slice through the hippocampus of one specimen at 3T (left) and 7T (right), demonstrated the enhanced detectability at 7T. Table 1: Measured T1 and T2 Figure 1: 3T and 7T specimens. Corresponding plaques are marked.
منابع مشابه
Assessing functional connectivity measures at 3T and 7T
Introduction: Functional connectivity, implied by inter-region correlation, has previously been reported in spontaneous resting state BOLD activity. Previous work has shown high correlation between BOLD fMRI signals from functionally related disparate brain regions e.g. 1 implying that brain activity in these regions is connected even in the absence of external stimuli. It is well known that as...
متن کاملIndirect sensitive MR detection of Aβ plaques with USPIO in Alzheimer transgenic mice
Introduction High field (>7T) and high resolution (<60μm) are needed in MR imaging for direct Aβ plaques visualization in Alzheimer disease [1]. USPIO-enhanced approach allows an increase of sensitivity and was evaluated in animal experiments and clinical studies as MRI markers for the diagnostic of neuroinflammatory disease associated with high macrophage phagocytic activity like multiple scle...
متن کاملDouble Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simultaneous BOLD and CBF acquisition
DABS (B); 7T BOLD images using DABS at 3 mm isotropic resolution (C) and 1.5x1.5x3 mm (D). 3T perfusion weighted (PW) images at 3 mm isotropic resolution using standard FAIR (E) and with DABS (F); 7T PW images DABS 3 mm isotropic resolution (G) and 1.5x1.5x3 mm (H). All images have overlaid activated regions. Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simu...
متن کاملIn vivo 1H NMR spectroscopy of the human brain at high magnetic fields: metabolite quantification at 4T vs. 7T.
A comprehensive comparative study of metabolite quantification from the human brain was performed on the same 10 subjects at 4T and 7T using MR scanners with identical consoles, the same type of RF coils, and identical pulse sequences and data analysis. Signal-to-noise ratio (SNR) was increased by a factor of 2 at 7T relative to 4T in a volume of interest selected in the occipital cortex using ...
متن کاملWater Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively
INTRODUCTION The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field. METHODS In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On R...
متن کامل