Implementation of a closed-loop reporting system for critical values and clinical communication in compliance with goals of the joint commission.
نویسندگان
چکیده
BACKGROUND Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals. METHODS A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design. RESULTS The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min. CONCLUSIONS We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The Joint Commission's goals.
منابع مشابه
Nonlinear Stabilizing Controller for a Special Class of Single Link Flexible Joint Robots
Joint flexibility is a very important factor to consider in the controller design for robot manipulators if high performance is expected. Most of the research works on control of flexible-joint robots in literature have ignored the actuator dynamics to avoid complexity in controller design. The problem of designing nonlinear controller for a class of single-link flexible-joint robot manipulator...
متن کاملIdentification and Control of MIMO Systems with State Time Delay (Short Communication)
Time-delay identification is one of the most important parameters in designing controllers. In the cases where the number of inputs and outputs in a system are more than one, this identification is of great concern. In this paper, a novel autocorrelation-based scheme for the state variable time-delay identification for multi-input multi-output (MIMO) system has been presented. This method is ba...
متن کاملRobust adaptive control of voltage saturated flexible joint robots with experimental evaluations
This paper is concerned with the problem of design and implementation a robust adaptive control strategy for flexible joint electrically driven robots (FJEDR), while considering to the constraints on the actuator voltage input. The control design procedure is based on function approximation technique, to avoid saturation besides being robust against both structured and unstructured uncertaintie...
متن کاملClinical Governance: The Challenges of Implementation in Iran
Background and Objectives: The Iranian Ministry of Health and Medical Education has introduced clinical governance as the accepted model of hospital healthcare improvement. Subsequently, a growing movement for implementing clinical governance in health facilities has emerged. This study aimed to explore the opinions of the relevant experts and executives to provide insight into current challen...
متن کاملShort Term Clinical Outcomes of Hook Plate Compared to Continuous Loop Double Endobutton Fixations in Acute Acromioclavicular Joint Dislocation
Background: This study was conducted to evaluate the clinical outcomes of acromioclavicular joint (ACJ) fixation with hook plate (HP) and continuous loop double endobutton fixation (CLDE) in treatment of the acute acromioclavicular joint (ACJ) dislocation. Methods: In this retrospective study, 8 patients with HP and 9 patients with CLDE fixations were compared for acute ACJ dislocations. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 56 3 شماره
صفحات -
تاریخ انتشار 2010