Patterns of Hemodialysis Catheter Dysfunction Defined According to National Kidney Foundation Guidelines As Blood Flow <300 mL/min

نویسندگان

  • Robert I. Griffiths
  • Britt B. Newsome
  • Geoffrey A. Block
  • Robert J. Herbert
  • Mark D. Danese
چکیده

Blood flow rate (BFR) <300 mL/min commonly is used to define hemodialysis catheter dysfunction and the need for interventions to prevent complications. The objective of this study was to describe patterns of unplanned BFR <300 mL/min during catheter hemodialysis using data from DaVita dialysis facilities and the United States Renal Data System. Patients were included if they received at least eight weeks of hemodialysis exclusively through a catheter between 08/04 and 12/06, and catheter hemodialysis was the first treatment modality following diagnosis of end-stage renal disease (first access), or it immediately followed at least one 30-day period of dialysis exclusively through a fistula or graft (replacement access). Actual BFR <300 mL/min despite a planned BFR ≥300 mL/min defined catheter dysfunction during each dialysis session. There were 3,364 patients, 268,363 catheter dialysis sessions, and 19,118 (7.1%) sessions with catheter dysfunction. Almost two-thirds of patients had ≥1 catheter dysfunction session, and 30% had ≥1 catheter dysfunction session per month. Patients with catheter as a replacement access had a higher rate of catheter dysfunction than those with a catheter as first access (hazard ratio: 1.13; P = 0.04). Catheter dysfunction affects almost one-third of catheter dialysis patients each month and two-thirds overall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Hemodialysis Catheter Dysfunction on Dialysis and Other Medical Services: An Observational Cohort Study

Practice guidelines define hemodialysis catheter dysfunction as blood flow rate (BFR) <300 mL/min. We conducted a study using data from DaVita and the United States Renal Data System to evaluate the impact of catheter dysfunction on dialysis and other medical services. Patients were included if they had ≥8 consecutive weeks of catheter dialysis between 8/2004 and 12/2006. Actual BFR <300 mL/min...

متن کامل

Relationship between blood flow in central venous catheters and hemodialysis adequacy.

Central venous catheter dysfunction is a frequent problem and often is defined as a blood flow <300 ml/min. This prospective, cross-sectional study included 259 patients and examined the relationship between catheter blood flow and dialysis adequacy as measured by urea reduction ratio (URR), single pool urea kinetics, and online effective ionic dialysance clearance. Dialysis adequacy at blood f...

متن کامل

In vivo effects of dialysate flow rate on Kt/V in maintenance hemodialysis patients.

It is generally assumed that hemodialysis adequacy is only minimally affected by increasing the dialysate flow rate (Qd). Recent in vitro studies showed that dialyzer urea clearance (Kd(urea)) may increase substantially more than expected in response to an increase in Qd. Because these studies implied that dialysis efficacy may benefit from greater Qds, we studied in vivo the effects of various...

متن کامل

High Prevalence of Cardiovascular Disease in End-Stage Kidney Disease Patients Ongoing Hemodialysis in Peru: Why Should We Care About It?

Purpose. To determine clinical, biochemical, and pharmacological characteristics as well as cardiovascular disease prevalence and its associated factors among end-stage kidney disease patients receiving hemodialysis in the main hemodialysis center in Lima, Peru. Methods. This cross-sectional study included 103 patients. Clinical charts were reviewed and an echocardiogram was performed to determ...

متن کامل

Dynamic venous access pressure ratio test for hemodialysis access monitoring.

BACKGROUND Early recognition of arteriovenous graft (AVG) dysfunction in hemodialysis (HD) patients followed by prompt corrective procedures reduces AVG thrombosis rates and lengthens access survival. We developed a method to prospectively monitor AVGs that uses an algorithm to calculate venous access pressure (VAP) during HD from the venous drip chamber pressure (VDP). METHODS Sham HD with b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011