Accuracy of Nurse-Performed Lung Ultrasound in Patients With Acute Dyspnea

نویسندگان

  • Nicola Mumoli
  • Josè Vitale
  • Matteo Giorgi-Pierfranceschi
  • Alessandra Cresci
  • Marco Cei
  • Valentina Basile
  • Barbara Brondi
  • Elisa Russo
  • Lucia Giuntini
  • Lorenzo Masi
  • Massimo Cocciolo
  • Francesco Dentali
چکیده

In clinical practice lung ultrasound (LUS) is becoming an easy and reliable noninvasive tool for the evaluation of dyspnea. The aim of this study was to assess the accuracy of nurse-performed LUS, in particular, in the diagnosis of acute cardiogenic pulmonary congestion. We prospectively evaluated all the consecutive patients admitted for dyspnea in our Medicine Department between April and July 2014. At admission, serum brain natriuretic peptide (BNP) levels and LUS was performed by trained nurses blinded to clinical and laboratory data. The accuracy of nurse-performed LUS alone and combined with BNP for the diagnosis of acute cardiogenic dyspnea was calculated. Two hundred twenty-six patients (41.6% men, mean age 78.7 ± 12.7 years) were included in the study. Nurse-performed LUS alone had a sensitivity of 95.3% (95% CI: 92.6-98.1%), a specificity of 88.2% (95% CI: 84.0-92.4%), a positive predictive value of 87.9% (95% CI: 83.7-92.2%) and a negative predictive value of 95.5% (95% CI: 92.7-98.2%). The combination of nurse-performed LUS with BNP level (cut-off 400 pg/mL) resulted in a higher sensitivity (98.9%, 95% CI: 97.4-100%), negative predictive value (98.8%, 95% CI: 97.2-100%), and corresponding negative likelihood ratio (0.01, 95% CI: 0.0, 0.07). Nurse-performed LUS had a good accuracy in the diagnosis of acute cardiogenic dyspnea. Use of this technique in combination with BNP seems to be useful in ruling out cardiogenic dyspnea. Other studies are warranted to confirm our preliminary findings and to establish the role of this tool in other settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Point-of-Care B-Line Lung Ultrasound in Comparison to NT-ProBNP for Screening Acute Heart Failure.

AIM The objective of this pilot study was to determine the accuracy of point-of-care B-line lung ultrasound in comparison to NT Pro-BNP for screening acute heart failure. MATERIALS AND METHODS An 8-zone lung ultrasound was performed by experienced sonographers in patients presenting with acute dyspnea in the ED. AHF was determined as the final diagnosis by 2 independent reviewers. RESULTS C...

متن کامل

Diagnostic Accuracy of Acute Appendicitis by Ultrasound in Hospital Emergency

Background Acute appendicitis is the most common medical condition requiring immediate abdominal surgery.Medical ultrasound is a non-intrusive, non-expensive and available diagnostic method. In this study, the accuracy of ultrasound in diagnosis of acute appendicitis in hospital emergency was evaluated. Materials and Methods This retrospective cohort study was performed at Ahvaz Imam Khomeini h...

متن کامل

Combination of lung ultrasound (a comet-tail sign) and N-terminal pro-brain natriuretic peptide in differentiating acute heart failure from chronic obstructive pulmonary disease and asthma as cause of acute dyspnea in prehospital emergency setting

INTRODUCTION We studied the diagnostic accuracy of bedside lung ultrasound (the presence of a comet-tail sign), N-terminal pro-brain natriuretic peptide (NT-proBNP) and clinical assessment (according to the modified Boston criteria) in differentiating heart failure (HF)-related acute dyspnea from pulmonary (chronic obstructive pulmonary disease (COPD)/asthma)-related acute dyspnea in the prehos...

متن کامل

Acute cardiogenic dyspnea in the emergency department: accuracy of lung ultrasound

Patients and methods 70 patients presenting with acute dyspnea have been enrolled. On admission every patient underwent to LUS and chest X-ray (CXR). Ultrasound findings of Interstitial Alveolar Syndrome (IAS), which correlate with an increase in interstitial lung water, were reported. On the results of LUS, the patients were attributed to 2 different diagnostic groups: Group 1: patients with c...

متن کامل

Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea

INTRODUCTION Determining the etiology of acute dyspnea in emregency department (ED) patients is often difficult. Point-of-care ultrasound (POCUS) holds promise for improving immediate diagnostic accuracy (after history and physical), thus improving use of focused therapies. We evaluate the impact of a three-part POCUS exam, or "triple scan" (TS) - composed of abbreviated echocardiography, lung ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016