The PHILOS plate for proximal humeral fractures--risk factors for complications at one year.

نویسندگان

  • Christian Spross
  • Andreas Platz
  • Kaspar Rufibach
  • Thomas Lattmann
  • Jens Forberger
  • Michael Dietrich
چکیده

BACKGROUND Since 2003, we have used the Proximal Humerus Interlocking System plate for treatment of proximal humeral fractures. Although many patients have good and excellent results, the reported rate of complications varies. We have focused on the complication rate and risk factors for complications 1 year after surgery. METHODS From 2003 until 2008, a total of 294 (223 women; 71 men; median age, 72.9) patients were included. General data were collected at the time of injury (Charlson Index, smoking, and steroid therapy). Fractures were classified (AO/OTA) retrospectively. The follow-up of 1 year included radiographs and Constant-Murley score for functionality. Complications and revision surgeries were analyzed specifically. RESULTS We found 83 (28.2%) patients with a total of 105 complications, requiring a total of 72 (24.5%) revision surgeries. The most frequent complication was screw cutout (33 of 294, 11.2%), because of secondary fracture displacement or avascular necrosis (AVN). AVN (20 of 294, 6.8%) was the main reason for secondary arthroplasty. Smoking more than 20 pack years had a significant impact on the complication rate. Fractures classified 11-A3 showed more implant failures. Fracture dislocations predisposed to secondary screw cutout and AVN. Patients without complications (211, 71.8%) achieved a median Constant-Murley score of 89 (40-100) points. CONCLUSION This study points out several predisposing factors for negative outcome after open reduction and internal fixation with the Proximal Humerus Interlocking System plate (fracture type: 11-A3, fracture dislocations, and smoking). Accounting for these, patient's risk for complications can be evaluated more individually and taken into consideration for the concept of treatment. Altering the surgical technique was associated with a significant reduction in the incidence of secondary screw cutout.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of “Plate” and “Screw” Views

Proximal humeral fractures are common injuries with increasing incidence, particularly in the aging population. Nondisplaced or minimally displaced fractures can be treated conservatively whereas surgical fixation is usually indicated in the cases of displaced fractures. Various surgical options have been used for treatment of these fractures. Good outcomes have been reported with use of the Pr...

متن کامل

Philos plate fixation for displaced proximal humeral fractures.

PURPOSE To evaluate the treatment outcome of Philos plate fixation for displaced proximal humeral fractures in 27 consecutive patients. METHODS 6 men and 21 women aged 22 to 85 (mean, 56) years underwent Philos plate fixation for displaced proximal humeral fractures. 11 patients were aged 60 years or younger and 16 older than 60 years. All fractures were closed with no associated injuries and...

متن کامل

The Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate.

BACKGROUND In the last fifty years since plate and screw osteosynthesis has been implemented in fracture treatment, osteosporotic bone fractures were observed as a special problem. Due to special histologic, anatomic, physical and biomehanic properties of osteoporotic changed bone the laws of biomechanics suggest that stable osteosynthesis for osteoporotic bone is necessary to increase the cont...

متن کامل

Use of a proximal humeral plate for a paediatric peri-prosthetic femoral fracture

In this case an 18-year-old female with cerebral palsy sustained a peri-prosthetic femoral fracture adjacent to a blade plate previously inserted for a femoral varus osteotomy. The injury was treated using a long proximal humeral locking plate. The existing blade plate was removed. The fracture was reduced and held, and a 10-hole PHILOS™ plate applied with near anatomical reduction. There were ...

متن کامل

Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.

Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of trauma and acute care surgery

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 2012