Bioaerosol sampling by a personal rotating cup sampler CIP 10-M.

نویسندگان

  • Peter Görner
  • Jean-François Fabriès
  • Philippe Duquenne
  • Olivier Witschger
  • Richard Wrobel
چکیده

High concentrations of bioaerosols containing bacterial, fungal and biotoxinic matter are encountered in many workplaces, e.g. solid waste treatment plants, waste water treatment plants and sewage networks. A personal bioaerosol sampler, the CIP 10-M (M-microbiologic), has been developed to measure worker exposure to airborne biological agents. This sampler is battery operated; it is light and easy to wear and offers full work shift autonomy. It can sample much higher concentrations than biological impactors and limits the mechanical stress on the microorganisms. Biological particles are collected in 2 ml of liquid medium inside a rotating cup fitted with radial vanes to maintain an air flow rate of 10 l min(-1) at a rotational speed of approximately 7,000 rpm. The rotating cup is made of sterilisable material. The sampled particles follow a helicoidal trajectory as they are pushed to the surface of the liquid by centrifugal force, which creates a thin vertical liquid layer. Sterile water or another collecting liquid can be used. Three particle size selectors allow health-related aerosol fractions to be sampled according to international conventions. The sampled microbiological particles can be easily recovered for counting, incubation or further biochemical analysis, e.g., for airborne endotoxins. Its physical sampling efficiency was laboratory tested and field trials were carried out in industrial waste management conditions. The results indicate satisfactory collection efficiency, whilst experimental application has demonstrated the usefulness of the CIP 10-M personal sampler for individual bioaerosol exposure monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory evaluation of the CIP 10 personal dust sampler.

The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow th...

متن کامل

Field Evaluation of Personal Sampling Methods for Multiple Bioaerosols

Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient c...

متن کامل

Pii: S0003-4878(99)00042-3

Existing samplers for the collection of bioaerosols have been designed with the aim of maintaining biological stability of the collected material, and in general do not select particles in accordance with international conventions for aerosol sampling. Many have uncharacterised sampling eciencies and few are designed as personal samplers. If standard personal dust samplers are used for bioaero...

متن کامل

Airborne Influenza A Is Detected in the Personal Breathing Zone of Swine Veterinarians

The 2009 H1N1 pandemic emphasized a need to evaluate zoonotic transmission of influenza A in swine production. Airborne influenza A virus has been detected in swine facilities during an outbreak. However, the personal exposure of veterinarians treating infected swine has not been characterized. Two personal bioaerosol samplers, the NIOSH bioaerosol sampler and the personal high-flow inhalable s...

متن کامل

Bioaerosol sampling for the detection of aerosolized influenza virus

BACKGROUND Influenza virus was used to characterize the efficacy of a cyclone-based, two-stage personal bioaerosol sampler for the collection and size fractionation of aerosolized viral particles. METHODS A Collison single-jet nebulizer was used to aerosolize the attenuated FluMist vaccine into a calm-air settling chamber. Viral particles were captured with bioaerosol samplers that utilize 2 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental monitoring : JEM

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2006