Streptavidin-biotinylated IgG conjugates: a simple procedure for reducing polymer formation.

نویسندگان

  • R B del Rosario
  • L A Baron
  • R G Lawton
  • R L Wahl
چکیده

Disulfide links of the IgG2ak anti-ovarian carcinoma antibody, 5G6.4, were site-specifically biotinylated [approximately 2 biotins/IgG2a] using a novel crosslinking procedure using the biotin derivatized ETAC (equilibrium transfer alkylation crosslink reagent) 1a. Complexation of ETAC 1a biotinylated 5G6.4 on a column of immobilized protein A at high dilution, followed by passage of [125I]streptavidin, washing and pH change leads to elution of a streptavidin-free product with a molecular mass in the 200-300 kDa range. By contrast, direct mixing with [125I]streptavidin rapidly gave larger oligomers of much greater than 669 and approximately 440-669 kDa molecular mass, respectively. The biodistribution of the 200-300 kDa complex showed significantly diminished liver, kidney and spleen uptake as well as higher blood activity than the 440-669 kDa complex. The methodology represent the first application of ETAC chemistry to disulfide-bond directed biotinylation of antibodies and the synthesis of streptavidin antibody conjugates which minimizes their polymerization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct time-resolved fluorescence immunoassay of progesterone in serum involving the biotin-streptavidin system and the immobilized-antibody approach.

We developed a direct competitive-type immunoassay for progesterone in serum that combines the advantages of the biotin-streptavidin system with the antibody-immunobilization approach. We synthesized biotinylated progesterone derivatives of five different proteins and, after initial evaluation of the conjugates, selected biotinylated bovine IgG-progesterone as the most suitable tracer. Progeste...

متن کامل

Novel application of streptavidin-hapten derivatives as protein-tracer conjugate in competitive-type immunoassays involving biotinylated detection probes.

To investigate the use of streptavidin-hapten derivatives as potential protein-tracer conjugates for competitive-type immunoassays, we labeled streptavidin with cortisol and compared biotin-binding activity of the conjugates with that of unlabeled streptavidin. In this model system, streptavidin labeled with one to approximately 17 cortisol molecules retained its capability to cross-link a biot...

متن کامل

Combination of DNA-directed immobilization and immuno-PCR: very sensitive antigen detection by means of self-assembled DNA-protein conjugates.

An assay for very sensitive antigen detection is described which takes advantage of the self- assembly capabilities of semi-synthetic conjugates of DNA and proteins. The general scheme of this assay is similar to a two-sided (sandwich) enzyme-linked immunoassay (ELISA); however, covalent single-stranded DNA-streptavidin (STV) conjugates, capable of hybridizing to complementary surface-bound DNA...

متن کامل

Streptavidin-polyvinylamine conjugates labeled with a europium chelate: applications in immunoassay, immunohistochemistry, and microarrays.

BACKGROUND The favorable properties of lanthanide chelates compared with conventional fluorescent probes have attracted considerable interest. A Eu(3+) chelator, 4,7-bis(chlorosulfophenyl)-1, 10-phenanthroline-2,9-dicarboxylic acid (BCPDA), has been synthesized previously. METHODS We here describe immunoassay, immunohistochemistry, and microarray applications of a new streptavidin-based unive...

متن کامل

Layer by layer assembly of biotinylated protein networks for signal amplification.

Described herein is a unique and inexpensive method that outperforms commercial methods that amplify the streptavidin-biotin recognition event. Amplification induced by streptavidin and biotinylated protein causes the formation of a large detectable polymer. This approach enjoys a 100-fold decrease in detection limit in comparison with the commercial methods.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 1992