Fritless capillary columns for HPLC and CEC prepared by immobilizing the stationary phase in an organic polymer matrix

نویسندگان

  • Chirica
  • Remcho
چکیده

A new design of immobilized particle separation media for capillary liquid chromatography and electrochromatography has been developed. A mixture of porogenic solvents and methacrylate-based monomers is pumped through a packed column to provide, following a polymerization step, an organic matrix capable of holding the sorbent particles in place, thus rendering the end frits unnecessary. The new columns demonstrate excellent chromatographic performance in both CEC (reduced plate height [h]=1.1-1.5) and micro LC modes (h = 2.2-2.5), while minimizing secondary interactions encountered when silica-based entrapment matrixes are employed. In addition to delivering mechanically robust columns, the methacrylate matrix provides a mechanism for fine tuning of the electroosmotic flow velocity when 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) is incorporated into the polymerization mixture.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fritless packed columns with great potential for use in capillary Electrochromatography

T he past several years have seen a significant resurgence of interest in cap i l l a ry electro ch ro m at ography(CEC), a hybrid technique that combines the high efficiency owing to the flow characteristics related to electroosmosis with the selectivity of high performance liquid chromatography(HPLC). In CEC, separations are generally carried out using fused silica capillaries packed with HPL...

متن کامل

A simple procedure for the preparation of fritless columns by entrapping conventional high performance liquid chromatography sorbents.

A rapid and direct method for immobilizing conventional high performance liquid chromatography (HPLC) packing material inside fritless capillaries has been developed. Due to the simple composition of the entrapment matrix (tetraethoxysilane, alkyltriethoxysilane, ethanol and water), straightforward manufacturing procedure and modest equipment requirement, the method can readily be transferred t...

متن کامل

Monolithic LC columns.

Recently, monolithic columns consisting of one piece of an organic polymer or silica with flow-through pores have been reported in the literature. These materials provide better stability and, more important, higher performance than conventional columns packed with particles. Although they can be prepared by various methods, monolithic columns prepared by the direct polymerization of monomers c...

متن کامل

Focusing Review Development and Pharmaceutical Applications of Functional Stationary Phases for Capillary Electrochromatography and Chiral Separation

We synthesized 3-(4-sulfo-1,8-naphthalimido)propyl-modified silica (SNAIP) for capillary electrochromatography (CEC). The unique structure of SNAIP contributed to the retention by three interactions including hydrophobic, electrostatic and interactions and the acceleration of electroosmotic flow at an acidic condition. The CEC employing SNAIP was successively applied to the rapid separations of...

متن کامل

Hybrid organic-inorganic phenyl monolithic column for capillary electrochromatography.

A novel hybrid organic-inorganic silica-based monolithic column possessing phenyl ligands for reversed-phase (RP) capillary electrochromatography (CEC) is described. The monolithic stationary phase was prepared by in situ co-condensation of tetraethoxysilane (TEOS) with phenyltriethoxysilane (PTES) via a two-step catalytic sol-gel procedure to introduce phenyl groups distributed throughout the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 72 15  شماره 

صفحات  -

تاریخ انتشار 2000