Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments.
نویسندگان
چکیده
We evaluated the influence of manual preflaring and torque on the failure rate of rotary nickel-titanium ProTaper instruments Shaping 1 (S1), Shaping 2 (S2), Finishing 1 (F1), and Finishing 2 (F2). These factors were evaluated using an in vitro method by calculating the mean number of Endo-Training-Blocks shaped before file breakage under different conditions. Group A (S1 on simulators with no preflaring) shaped 10 blocks before failure, group B (S1 on manually preflared simulators) shaped 59 blocks (p<0.01 versus group A), group C (S2 with low torque) shaped 28 blocks, group D (S2 with high torque) shaped 48 blocks (p<0.01 versus group C), group E (F1 with low torque) shaped eight blocks, group F (F1 with high torque) shaped 23 blocks (p<0.01 versus group E), group G (F2 with low torque) shaped four blocks, and group H (F2 with high torque) shaped 11 blocks (p<0.01 versus group G). Manual preflaring creates a glide path for the instrument tip and is a major determinant in reducing the failure rate of these rotary nickel-titanium files. All instruments worked better at high torque.
منابع مشابه
Influence of cervical preflaring on determination of apical file size in mandibular molars: SEM analysis.
This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working ...
متن کاملPathFileTM: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring
NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...
متن کاملPathFiles: A New Rotary Nickel-Titanium Instrument for Mechanical Glide Path and Preflaring
NiTi instrument separation is a serious concern in endodontic therapy. The analysis of NiTi files after torsional fracture reveals that the majority of torsional separations occur in the last mm. of the files and in the files with lower taper and/ or diameter. Consequentely, the tip of the smaller files presents the higher risk of torsional fracture and should be protected using low torque moto...
متن کاملIn-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation
Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...
متن کاملShaping potential of manual NiTi K-File and rotary ProTaper and analyzing the final outcome of shaped canals using CT.
AIM To assess and compare the shaping potential of manual NiTi K-files and Rotary ProTaper instruments in narrow canals using CT. OBJECTIVE To assess the shaping potential of manual NiTi K-files and Rotary ProTaper and analyzing the final outcome of shaped canals using CT and determining different variables, like • Working time • Change in volume • Change in cross-sectional area. MATERIALS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2004