Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty

نویسندگان

  • Thomas Baad-Hansen
  • Søren Kold
  • Poul Torben Nielsen
  • Mogens Berg Laursen
  • Poul Hedevang Christensen
  • Kjeld Soballe
چکیده

BACKGROUND Trabecular metal has shown promising results in experimental studies of bone ingrowth. Several clinical studies support these results. However, until now, no randomized clinical radiostereometric analysis (RSA) studies have been published. In this randomized RSA trial, we compared a new acetabular cup with a surface made of tantalum trabecular metal and a cup with a titanium fiber-mesh surface. PATIENTS AND METHODS Between 2004 and 2006, we operated 60 patients with noninflammatory hip arthritis. The patients were randomized to receive either an uncemented cup with a titanium fiber-mesh surface (Trilogy cup) or a cup with a trabecular tantalum surface (Monoblock cup). After 2 years, 50 patients had completed the study. The primary endpoint was cup migration within the first 2 years after surgery; the secondary endpoints were change in bone mineral density and Harris hip score at 3 months. RESULTS Both cup types showed excellent fixation. RSA revealed minimal translation and rotation at 2 years. There was no statistically significant difference between the cup types with regard to translation. However, less rotation along the transverse axis was seen in the trabecular metal cups than in the fiber mesh cups: mean -0.01º (95% CI: -0.11 to 0.12) for trabecular metal cups and -0.60º (-0.72 to -0.48) for fiber-mesh cups (p = 0.04). The degree of periprosthetic bone loss was similar between the cup types in any of the regions of interest at 2 years of follow-up. 3 months postoperatively, we found a similar increase in Harris hip score in both groups: from around 50 to over 90. INTERPRETATION We found promising early results concerning fixation of trabecular metal components to the acetabular host bone. However, we recommend a longer observation period to evaluate the outcome of this new cup design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polyethylene wear in total hip arthroplasty.

Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined poly...

متن کامل

A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.

We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions,...

متن کامل

Excellent results of primary THA using a highly porous titanium cup.

Cementless acetabular cups for primary total hip arthroplasty have had excellent results, with failure rates typically less than 5% at up to 10-year follow-up. Tritanium is a 3-dimensional metal interface that has been used for porous biological fixation. The purpose of this study was to review the clinical and radiographic results of the use of Tritanium cups (Stryker Orthopaedics, Mahwah, New...

متن کامل

A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.

Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled trial receiving either titanium or tantalum cups (n=46). The novel method estimated the center of the...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011