Estimation of mean left atrial pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow.

نویسندگان

  • H F Kuecherer
  • I A Muhiudeen
  • F M Kusumoto
  • E Lee
  • L E Moulinier
  • M K Cahalan
  • N B Schiller
چکیده

To determine whether pulmonary venous flow and mitral inflow measured by transesophageal pulsed Doppler echocardiography can be used to estimate mean left atrial pressure (LAP), we prospectively studied 47 consecutive patients undergoing cardiovascular surgery. We correlated Doppler variables of pulmonary venous flow and mitral inflow with simultaneously obtained mean LAP and changes in pressure measured by left atrial or pulmonary artery catheters. Among the pulmonary venous flow variables, the systolic fraction (i.e., the systolic velocity-time integral expressed as a fraction of the sum of systolic and early diastolic velocity-time integrals) correlated most strongly with mean LAP (r = -0.88). Of the mitral inflow variables, the ratio of peak early diastolic to peak late diastolic mitral flow velocity correlated most strongly with mean LAP (r = 0.43), but this correlation was not as strong as that with the systolic fraction of pulmonary venous flow. Similarly, changes in the systolic fraction correlated more strongly with changes in mean LAP (r = -0.78) than did changes in the ratio of peak early diastolic to peak late diastolic mitral inflow velocity (r = 0.68). We conclude that in the surgical setting observed, pulmonary venous flow from transesophageal pulsed Doppler echocardiography can be used to estimate mean LAP. This technique may provide a rapid, simple, and relatively noninvasive means of gauging this variable in patients undergoing intraoperative transesophageal echocardiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow.

OBJECTIVES The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of...

متن کامل

Left main coronary artery to left atrial fistula causing mild pulmonary hypertension.

A73-year-old man with a 6-month history of exertional chest tightness and dyspnea was referred for evaluation. No risk factors for coronary atherosclerosis were present. Left cardiac catheterization revealed coronary arteries without significant stenoses and mildly impaired left ventricular function (ejection fraction, 55%). A fistula from the main stem of the left coronary artery to the left a...

متن کامل

Cor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report

  Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium  through restrictive opening to the low-pressure, dis...

متن کامل

Altered left atrial compliance after atrial appendectomy. Influence on left atrial and ventricular filling.

Previous studies have shown regional differences in atrial distensibility. We studied 12 open-chest dogs to test the hypothesis that left atrial compliance is decreased after removal of the left atrial appendage and to determine the effect of altered atrial compliance on atrial reservoir and conduit function. Sonomicrometer crystal pairs were used to measure the long- and short-axis diameters o...

متن کامل

Doppler estimation of left ventricular filling pressures in patients with hypertrophic cardiomyopathy.

BACKGROUND Conventional Doppler parameters are unreliable for estimating left ventricular (LV) filling pressures in hypertrophic cardiomyopathy (HCM). This study was undertaken to evaluate flow propagation velocity by color M-mode and early diastolic annular velocity (Ea) by tissue Doppler 2 new indices of LV relaxation, combined with mitral E velocity for estimation of filling pressures in HCM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 1990