BACKGROUND Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac output (CO). This study tested that hypothesis in healthy volunteers exposed to central hypovolemia by head-up tilt. METHODS Thirteen healthy volunteers were exposed to central hypovolemia by 45° head-up tilt while breathing through a facemask with 7.5 cmH2O inspiratory and/or expiratory resistors. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation (SPV), pulse pressure variation and stroke volume variation . Pulse contour analysis determined stroke volume (SV) and CO and we evaluated whether APV could detect a 10 % decrease in CO. RESULTS During head-up tilt SV decreased form 91 (±46) to 55 (±24) mL (mean ± SD) and CO from 5.8 (±2.9) to 4.0 (±1.8) L/min (p < 0.05), while heart rate increased (65 (±11) to 75 (±13) bpm; P < 0.05). Systolic pressure decreased from 127 (±14) to 121 (±13) mmHg during head-up tilt, while SPV tended to increase (from 21 (±15)% to 30 (±13)%). Yet during head-up tilt, a SPV ≥ 37 % predicted a decrease in CO ≥ 10 % with a sensitivity and specificity of 78 % and 100 %, respectively. CONCLUSION In spontaneously breathing healthy volunteers combined inspiratory and expiratory resistors enhance SPV during head-up tilted induced central hypovolemia and allow identifying a 10 % reduction in CO. Applying inspiratory and expiratory resistors might detect a fluid deficit in spontaneously breathing patients. TRIAL REGISTRATION ClinicalTrials.gov number NCT02549482 Registered September 10(th) 2015.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial pressure variations as parameters of brain perfusion in response to central blood volume depletion and repletion

RATIONALE A critical reduction in central blood volume (CBV) is often characterized by hemodynamic instability. Restoration of a volume deficit may be established by goal-directed fluid therapy guided by respiration-related variation in systolic- and pulse pressure (SPV and PPV). Stroke volume index (SVI) serves as a surrogate end-point of a fluid challenge but tissue perfusion itself has not b...

متن کامل

Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study

INTRODUCTION Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce h...

متن کامل

Spontaneous Breathing Trial a Reliable Method for Weaning in Children

Introduction  Mechanical ventilation may be lifesaving intervention,It can be associated with complications,Thus,successful weaning is constitutive.One of the factors which is  important in successful weaning is  method of weaning. It is shown that  weaning is conducted successfully by using Spontaneous Breathing Trial (SBT) through T-piece and pressure support (PS) ventilation.But few studies ...

متن کامل

Passive leg raising predicts fluid responsiveness in the critically ill.

OBJECTIVE Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN Prospective study. SETTING Medical intensive care unit of ...

متن کامل

Assessment of fluid responsiveness in patients under spontaneous breathing activity.

To assess fluid responsiveness in patients under spontaneous breathing activity ventilation remains a challenge for intensive care physicians. Much of the knowledge on heart-lung interactions and dynamic indexes of fluid responsiveness may not be useful for these patients. Historically, the most frequently used variables to guide fluid responsiveness on this population have been the static prel...