Different strategies for Humphrey automated perimetry: FASTPAC, SITA standard and SITA fast in normal subjects and glaucoma patients.

نویسندگان

  • X Roggen
  • K Herman
  • L Van Malderen
  • M Devos
  • W Spileers
چکیده

PURPOSE To evaluate the influence on examination time and test quality of the recently introduced SITA strategies of the Humphrey Field Analyzer. METHODS The sample consisted of 41 subjects (19 normal subjects and 22 glaucoma patients), all experienced in automated perimetry, ranging in age from 24 to 83 years. One eye of each patient was examined with the HC30-2 program using the FASTPAC (FP) and SITA Standard (SS) or SITA Fast (SF) strategy on the same day, in random order. Examination time was evaluated as a function of the strategy. To evaluate the test quality both regional and global visual field parameters were analyzed. Global parameters included mean deviation (MD) and pattern standard deviation (PSD). Regional parameters (mean and maximum loss) were calculated to estimate the extent and the depth of localized visual field defects. For this purpose each visual field was divided in 4 quadrants and in 10 clusters as defined in the glaucoma hemifield test. RESULTS 1. There is a considerable test time reduction from FASTPAC over SITA Standard to SITA Fast for comparable MD and PSD values. On average, the SITA Fast test duration is half that of the FASTPAC procedure. For each strategy, the test duration increases for increasing visual field loss. 2. Between all three strategies, there is a good correlation for the global indices (MD, PSD) 3. For the regional indices (mean loss, maximum loss) the same high correlation exists. CONCLUSION The SITA strategy causes a significant test time reduction without decreasing the test quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The SITA perimetric threshold algorithms in glaucoma.

PURPOSE To determine the within-visit between-algorithm and the within-algorithm between-visit differences in sensitivity for the SITA Standard, SITA Fast, FASTPAC, and Full Threshold algorithms in stable primary open angle glaucoma. METHODS One designated eye from each of 29 patients (age 67.3 +/- 10.2 years; mean +/- SD) experienced in automated perimetry was examined with the four algorith...

متن کامل

Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.

PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...

متن کامل

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...

متن کامل

Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma

Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field ...

متن کامل

A comparison of perimetric results with the Medmont and Humphrey perimeters.

BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin de la Societe belge d'ophtalmologie

دوره 279  شماره 

صفحات  -

تاریخ انتشار 2001