Benefits of high-frequency audiometry in monitoring hearing sensitivity of patients administered ototoxic medications are well established. High-frequency thresholds have been reported to be variable, due in part to small differences in the placement of the earphone diaphragm over the opening of the ear canal. Reliability may be improved by using insert earphones (ER-2) when obtaining high-frequency thresholds. The purposes of this study were to determine high-frequency threshold test-retest reliability using Koss HV/1A+ and ER-2 earphones and to determine if significant differences are present between high-frequency thresholds obtained using these two earphones. Results obtained on 40 ears of 20 normal hearing adults revealed that differences between the test and retest thresholds for each earphone were not significant. Intrasubject threshold differences between the test and retest thresholds for each earphone were, for the most part, within +/- 10 dB at all test frequencies. Further, significantly greater intensity was required to measure threshold when using the ER-2 earphone when compared to the Koss HV/1A+ at all test frequencies.
منابع مشابه
Effects of background noise on earphone thresholds.
Real-ear attenuation at threshold (REAT) and monaural pure-tone thresholds were determined for normally hearing adults using a supra-aural, Audiocup, and insert earphone. The thresholds were obtained in quiet and in background noises approximating the maximum permissible ambient noise levels (MPANLs) allowed in an audiometric test room specified by ANSI S3.1-1991 and OSHA (1983). The supra-aura...
متن کاملReference threshold levels for an ER-3A insert earphone.
The purpose of this study was to obtain normal hearing thresholds for an ER-3A insert earphone as a contribution for future standardization and for comparison with previous studies and interim ANSI and ISO insert earphone reference equivalent threshold sound pressure levels (RETSPLs). Hearing thresholds were obtained on each ear of 48 normal-hearing subjects from 125 to 8000 Hz using ER-3A and ...
متن کاملNewborn hearing thresholds measured by both insert and earphone methods.
Auditory brainstem response (ABR) absolute thresholds were obtained from 31 ears of 28 newborns using both the insert and the earphone methods to deliver the stimuli. The two estimates on each ear were acquired in a single test session, and they differed by 10 dB or less in all cases. The results suggest that when the earphone is used, it rarely if ever collapses the ear canal to cause an artif...
متن کاملReference equivalent threshold levels for pure tones and 1/3-oct noise bands: insert earphone and TDH-49 earphone.
Reference equivalent threshold sound pressure levels (RETSPLs) were determined for 20 subjects for pure tones and 1/3-oct noise bands. Two transducers were used: a Telephonics TDH-49 earphone mounted in an MX-41/AR cushion, and a Danavox SMW insert earphone coupled to an "HA-2" earmold. RETSPLs for pure tones transduced by the TDH-49 earphone were very similar to those published previously. For...
متن کاملSpectral changes produced by earphone-cushion reproduction of hearing aid-processed signals.
This investigation was conducted to assess the extent to which hearing aid-processed signals present an acoustic signal to the subject which has a frequency response equivalent to that which the hearing aid itself would have provided. The frequency response of a hearing aid receiver which was coupled directly to the ear canal ("aided" condition) was compared with the frequency response of the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 3 6 شماره
صفحات -
تاریخ انتشار 1992