BACKGROUND Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). METHODS A sample of 6 females and 4 males (mean age 29.1 ± 7.2 years, mean BMI 25.5 ± 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm × 47.1mm footprint by two operators in the same scanning session. RESULTS Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. CONCLUSIONS The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function.
منابع مشابه
Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
BACKGROUND Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end...
متن کاملReliability of ultrasound imaging in the assessment of the dorsal Lisfranc ligament
BACKGROUND The Lisfranc ligament plays an integral role in providing stability to the midfoot. Variable clinical presentations and radiographic findings make injuries to the Lisfranc ligament notoriously difficult to diagnose. Currently, radiographic evaluation is the mainstay in imaging such injuries; however, ultrasound has been suggested as a viable alternative. The objective of this study w...
متن کاملاستفاده از سازه های ارزشمندی و رضایتمندی برای سنجش اثربخشی نظامهای یادگیری الکترونیکی
This paper has employed a novel approach for determining effectiveness of electronic learning systems. This new approach employed importance and satisfaction structures for measurement of electronic learning systems’ effectiveness from viewpoint of their users. Hadith Science Virtual College in Rey was surveyed as case study. Two matrix analysis tools of “importance-satisfaction matrix” and “...
متن کاملMOCA ARM: Analog Reliability Measurement based on Monte Carlo Analysis
Due to the expected increase of defects in circuits based on deep submicron technologies, reliability has become an important design criterion. Although different approaches have been developed to estimate reliability in digital circuits and some measuring concepts have been separately presented to reveal the quality of analog circuit reliability in the literature, there is a gap to estimate re...
متن کاملرابطه فعالیت الکترومیوگرافی و تغییر ضخامت عضلات دیواره ی طرفی شکم در حین انقباض عضلات کف لگن در زنان سالم
Objective: To asses relationship between abdominal muscles superficial Electromyography (EMG) and ultrasound measurement during Pelvic Floor Muscles (PFM) contraction in healthy people. Methods: 15 healthy women participated in the study. Their abdominal muscles activation (transversus abdominis, internal oblique and external oblique muscles) was measured by EMG and sonography during maximal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gait & posture
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2014