Intrapulmonary effects of setting parameters in portable intrapulmonary percussive ventilation devices.

نویسندگان

  • Michel Toussaint
  • Marie-Charlotte Guillet
  • Stéphanie Paternotte
  • Philippe Soudon
  • Jurn Haan
چکیده

BACKGROUND Despite potential benefits of intrapulmonary percussive ventilation (IPV) in various respiratory diseases, the impact of setting parameters on the mechanical effects produced by IPV in the lungs is unknown. We hypothesized that changing the parameters on IPV would modulate these effects. This in vitro study aimed at comparing the changes in intrapulmonary effects resulting from changes in parameters in 3 portable IPV devices (IMP2, Impulsator, and Pegaso). METHODS Parameters were set in 72 combinations of frequency (90-250 cycles/min), inspiratory to expiratory (I/E) time ratio (from 1/2 to 3/1), and pressure (10-60 cm H(2)O). Four resulting effects were recorded on a test lung via a pneumotachometer: the expiratory to inspiratory flow ratio (E/I flow ratio), the PEEP, the ventilation, and the percussion. Percussion was assessed by the end-slope of the pressure curve. Analysis of variance was used for data analysis. RESULTS E/I flow ratio increased with increasing I/E time ratio (P < .001). The Pegaso produced the lowest E/I flow ratio. PEEP raised 6 cm H(2)O in both IMP2 and Impulsator, and 17 cm H(2)O in the Pegaso with increasing frequency (P < .01), pressure, and I/E time ratio (P < .001). In all devices, ventilation increased with increasing pressure and decreasing frequency (P < .001). Percussion increased with increasing frequency and decreasing I/E time ratio (P < .001), and with increasing pressure when I/E time ratio was 1/1 or less. The Pegaso provided the poorest percussion. CONCLUSIONS This study suggests that changing the parameters considerably modulates the mechanical effects produced by portable IPV devices in the lungs. Increasing frequency increased PEEP and percussion, but decreased ventilation. Increasing I/E time increased PEEP and E/I flow ratio, and decreased percussion. Finally, increasing pressure increased PEEP and ventilation. The Pegaso produced the highest PEEP, least percussion, and smallest change in E/I flow ratio.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapulmonary percussive ventilation improves the outcomes of helmet ventilation.

Questions: In adults with an acute exacerbation of chronic obstructive pulmonary disease (COPD) receiving non-invasive positive pressure ventilation (NIV), is intrapulmonary percussive ventilation (IPV) feasible? Does IPV improve outcomes compared to manual airway clearance techniques? Design: Randomised, controlled trial with concealed allocation. Setting: Intensive care unit of a tertiary hos...

متن کامل

Intrapulmonary percussive ventilation improves the outcomes of helmet ventilation

Questions: In adults with an acute exacerbation of chronic obstructive pulmonary disease (COPD) receiving non-invasive positive pressure ventilation (NIV), is intrapulmonary percussive ventilation (IPV) feasible? Does IPV improve outcomes compared to manual airway clearance techniques? Design: Randomised, controlled trial with concealed allocation. Setting: Intensive care unit of a tertiary hos...

متن کامل

The Usage of Intrapulmonary Percussive Ventilation

Mechanism of action Intrapulmonary percussive ventilation (IPV) is a form of high frequency oscillatory ventilation that can be used via mouthpiece, mask interface, or inline with artificial airway or mechanical ventilation. IPV was designed to improve mucus clearance and recruit obstructed bronchi and alveoli using a lung protective strategy; it avoids barotrauma caused by over-inflation of pr...

متن کامل

Acute effects of intrapulmonary percussive ventilation in COPD patients assessed by using conventional outcome parameters and a novel computational fluid dynamics technique

OBJECTIVE Chest physiotherapy enhances sputum evacuation in COPD patients. It can be applied as a single technique or as a combination of techniques including intrapulmonary percussive ventilation (IPV). Recently developed assessment techniques may provide new insights into the effect of airway clearance techniques. PARTICIPANTS Five moderate to severe COPD patients (three females and two mal...

متن کامل

Comparison of lung deposition in two types of nebulization: intrapulmonary percussive ventilation vs jet nebulization.

BACKGROUND So-called intrapulmonary percussive ventilation (IPV), frequently coupled with a nebulizer, is increasingly used as a physiotherapy technique; however, its physiologic and clinical values have not been rigorously assessed. STUDY OBJECTIVE To compare in vitro and in vivo characteristics of the nebulizer of the IPV device (Percussionaire; Percussionaire Corporation; Sandpoint, ID) wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2012