V-shaped double-row distal triceps tendon repair: a novel technique using unicortical button fixation
نویسندگان
چکیده
BACKGROUND This report was designed to present a novel technique combining suture anchor and unicortical button fixation for distal triceps tendon repair. TECHNICAL DESCRIPTION For anatomical reinsertion of an acute distal triceps tendon rupture, two suture anchors and one unicortical button forming a V-shaped configuration were used. The operative approach is described in detail. RESULTS Excellent clinical and functional results were achieved in the early postoperative phase. The patient reached full elbow range of motion and extension muscle strength (5/5) compared to the uninjured arm 12 weeks after surgery. Complications did not occur. CONCLUSION This is the first report using unicortical button fixation in distal triceps tendon repair with promising preliminary results. LEVEL OF EVIDENCE Technical description, case report, Level V.
منابع مشابه
Biomechanical in vitro validation of intramedullary cortical button fixation for distal biceps tendon repair: a new technique.
BACKGROUND Extramedullary cortical button-based fixation for distal biceps tendon ruptures exhibits maximum load to failure in vitro but cannot restore the anatomic footprint and has the potential risk for injury to the posterior interosseous nerve. HYPOTHESIS Double intramedullary cortical button fixation repair provides superior fixation strength to the bone when compared with single extram...
متن کاملDistal triceps tendon repair using Krakow whipstitches, K wires, tension band and double drilling technique: a case report
INTRODUCTION The management of distal triceps tears must address each patient's medical and functional status: in general, the literature has described satisfactory nonsurgical treatment in tears less than 50%. Tears greater than 50% are treated nonsurgically in a sedentary person and surgically in active patients. Complete tears are generally managed surgically: most reported repair techniques...
متن کاملTriceps brachii distal tendon reattachment with a double-row technique.
Case reports and small series have reported variable results regarding the treatment of choice for patients with triceps brachii tendon ruptures. Early surgical repair has been recommended for acute complete ruptures of the triceps brachii distal tendon to prevent late functional disability. However, controversy exists regarding the optimum surgical technique of reattachment. In addition, vario...
متن کاملReconstruction of chronic tearing of the distal triceps using the double-row configuration: technical note☆
Tearing of the distal triceps is uncommon and may be difficult to diagnose, especially in situations of partial tearing. Imaging methods such as ultrasonography and magnetic resonance imaging should be used to confirm the diagnosis and define the extent of the injury. The preferred treatment for complete tearing of the triceps is surgical, unlike in cases of partial tearing, in which the treatm...
متن کاملDistal Biceps and Triceps Injuries
Background Rupture of the distal biceps and triceps tendons are relatively uncommon injuries typically occurring in middle-aged males as a result of eccentric loading of the tendon. Methods A literature search was performed and the authors' personal experiences reported. Results This review discusses the diagnosis, indications and guidelines for management of these injuries and provides a d...
متن کامل