Collinear laser - beam — ion - beam measurement of the mean lifetime of the Ar II 4 p ' F 7 & 2 level

نویسنده

  • Jian Jin
چکیده

The mean lifetime w of the 4p' 'F7/2 level of Ar II has been measured using a variant of the collinear laser-beam —fast-ion-beam spectroscopy technique. Our variant requires no mechanical motion or laser frequency tuning. The result is ~=8.414+0.025 ns in agreement with an earlier, comparably precise, measurement based on a crossed laser —ion-beam technique. The result lies above all theoretical calculations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro-channels over the glass surface made by interaction of Ar+ laser beam and Ag+/Na+ ion-exchanged glasses

Micro-channels are made over the Ag+/Na+ ion-exchanged soda-lime glass surface by interaction of an intense Ar+ laser beam and the silver ions inside the glass matrix. The Ar+ laser beam reduces the Ag+ ions inside the matrix. The Ag+ atoms aggregate into silver nano-clusters around the interaction area, inside the glass matrix. Aggregation of the silver atoms and the thermal effects of the int...

متن کامل

Analyzing the Propagation Behavior of a Gaussian Laser Beam through Seawater and Comparing with Atmosphere

Study of the beam propagation behavior through oceanic media is a challenging subject. In this paper, based on generalized Collins integral, the mean irradiance profile of Gaussian laser beam propagation through ocean is investigated. Power In Special Bucket (PIB) is calculated. Using analytical expressions and calculating seawater transmission, the effects of absorption and scattering on beam ...

متن کامل

Altitude measurement using laser beam reflected from water surface

In this paper altitude measurement from water surface using laser beam is presented. Research data indicate that the reflection of infrared waves from water surface is about zero and it is less than 2% for visible radiations. Phase-shift and heterodyne technique was used for the measurement, and the laser beam ( mW p nm 10 , 700 = = l ) was modulated by a sine wave having a fixed frequency....

متن کامل

Measurement of the 2s 2p2(4P) 3s 3P2 lifetime in N II by beam-foil-laser spectroscopy

An accurate value for the radiative lifetime of the 2s 2p~(~P) 3s ~P~ level in N II has been obtained using the beam-foil-laser spectroscopy method. The result (T = 0.456 ± 0.020 ns ) is shorter than the beam-foil lifetime values reported previously for the 3s' ~P term. No theoretical value for the lifetime of this term is available at the present time.

متن کامل

The Effect of Polarized Laser Radiation on Viscoelastic Properties of Soft Tissue

Background: Laser-tissue interaction on low-level laser therapy (LLLT) has widespread medical applications (e.g., improved wound healing). The tensile strength of radiated tissue by LLLT is known to be increased mainly because of cross collagen bands developed after radiation.Objective: In this work, we studied the instantaneous effect of radiation of polarized laser beam on the viscoelastic ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011