Comparative Evaluation of Shear Bond Strength of Metallic Brackets With Two Bonding Agents With and Without Saliva Contamination

نویسندگان

  • Mashallah Khanehmasjedi
  • Mohammad Ali Naseri
  • Samaneh Khanehmasjedi
چکیده

Objectives: The present study was carried out to compare the shear bond strength of metallic brackets bonded with single Bond and Assure bonding agents under dry and saliva contamination conditions. Materials and Methods: A total 60 sound premolar teeth were selected for the purpose of this in vitro study and stainless steel brackets were bonded on enamel surfaces with single bond and assure bonding agents under a dry condition or with salivary contamination. The shear bond strength values of the brackets were measured in a universal testing machine. The adhesive remnant index (ARI) scores were determined after debonding of the brackets under a stereomicroscope. One-way ANOVA was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (P < 0.001). The frequencies of ARI scores were analyzed with Kruskal-Wallis test. Results: The bond strength values of brackets to tooth structure were 9.29 ± 8.56 and 21.25 ± 8.93 MPa with the use of Assure resin bonding agent under saliva contamination and dry conditions, respectively. These values were 10.13 ± 6.69 and 14.09 ± 6.6 MPa, respectively, under the same conditions with the use of single bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (P < 0.001). There were no significant differences in the ARI scores between the different study groups. Conclusions: Application of single bond and assure bonding agents resulted in adequate bond strength of brackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared to dry conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

BACKGROUND This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. METHODS Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength...

متن کامل

Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets

Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...

متن کامل

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

متن کامل

Effect of saliva and blood contamination on shear bond strength of cured dentin adhesives

Effect of saliva and blood contamination on shear bond strength of cured dentin adhesives Dr. E. Yassini* - Dr. E. Shidoush** *- Professor of Operative Dentistry Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. ** - Dentist. Background and Aim: Achieving good moisture control is a common problem encountered in restorative dentistry, especially after applying and curing dent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016