High‐resolution micro‐CT scanning as an innovative tool for evaluating dental hard tissue development

نویسندگان

  • Guangyan Dong
  • Qianqian Dong
  • Yi Liu
  • Beiyan Lou
  • Jin Feng
  • Kejing Wang
  • Xuedong Zhou
  • Hongkun Wu
چکیده

Microcomputerized tomography (micro-CT) allows discriminating very smal lchanges in dental hard tissue volumes. The aim of the present study was to create a new method for obtaining high-resolution, three-dimensional images of dental hard tissue development using micro-CT, and to observe the changes in dental hard tissue development and composition in growing rat pups. Tooth germs from rats at the end of the 20-day embryonic period (E20) and during the neonatal period (D1-14) were subjected to micro-CT. Three-dimensional reconstructions were analyzed to compare dental hard tissue formation and mineralization during the different development periods. Scanning electron microscopy and energy dispersive spectroscopy were used to confirm mineral density (MD). Dental hard tissue began to form during the E20, but the process was slow and resulted in minimal deposition. Hard tissue volume increased by approximately 0.040 mm3/day from E20 to D3, and by 0.12-0.42 mm3/day after D3, peaking at 0.42 mm3/day at D12. This increase in hard tissue volume resulted in continuous increases in hard tissue thickness, from 90.0 ± 20.7 μm at E20 to 545.2 ± 14.1 μm by D14. MD was 298 ± 3.1 mg HA/cm at E20 and increased to 678.2 ± 6.1 mg HA/cm by D14. The degree of calcification also progressively increased during the first 14 days of development. Dental MD was strongly associated with calcification. This study indicates that micro-CT is a nondestructive, high-resolution, reliable, and innovative tool for the evaluation of volume and MD of dental hard tissues during development. Micro-CT minimizes artifacts caused by sample preparation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage an...

متن کامل

Nano-computed tomography: current and future perspectives

The development of novel imaging technologies amplifies the excellence of scientific dental research. Significant technological advances in imaging have been introduced over the years in the field of restorative dentistry and endodontics. X-ray micro-computed tomography (micro-CT) systems were developed in the early 1980s, producing voxels in the range of 5 50 μm. These micro-CT systems offer a...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture

BACKGROUND The role of bone structure, one component of bone quality, has emerged as a contributor to bone strength. The application of high-resolution imaging in evaluating bone structure has evolved from an in vitro technology for small specimens to an emerging clinical research tool for in vivo studies in humans. However, many technical and practical challenges remain to translate these tech...

متن کامل

Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition

Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014