Assessment of Environmentally Friendly Refrigerants for Window Air Conditioners

نویسندگان

  • Bo Shen
  • Pradeep Bansal
  • Bo SHEN
  • Pradeep BANSAL
چکیده

This paper presents technical assessment of environmentally friendly refrigerants as alternatives to R410A for window air conditioners. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R410A. A detailed heat pump design model (HPDM) was calibrated with the baseline data and was used to assess the comparative performance of the WAC with alternative refrigerants. The paper discusses the advantages and disadvantages of each refrigerants and their suitability for window air conditioners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Window Air Conditioner with Orthodox Refrigerants

The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper,&#10 the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014