Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

نویسندگان

  • H. V. Groesdonk
  • H. Paarmann
  • J. Fassl
  • H. Kiefer
  • J. Ender
چکیده

Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 patients undergoing elective coronary artery bypass grafting surgery. Interventions: None Measurements: 900 paired cardiac output measurements were obtained by pulse contour analysis following transpulmonary thermodilution equilibration by the PiCCO system (PiCCO, Pulsion, Munich, Germany) and by the HemoSonic esophageal doppler monitor (HemoSonic 100; Arrow International, Reading, PA). Measurements were performed within the first hour after induction of anesthesia. Results: Bland-Altman analysis of the complete data set showed a mean difference (bias) of 0.12 l/min (95% CI -0.06 to -0.18) with limits of agreement + 1.8 l/min to -1.6 l/min (upper 95% CI 1.78 to 1.98; lower 95% CI -1.74 to -1.54), the percentage error was + 37% to -44.5%. Transesophageal echo-Doppler cardiac output closely correlated (r = 0.75, p < 0.0001) with pulse-contour analyses cardiac output. Conclusions: Several studies have shown the accuracy of calibrated pulse contour cardiac output measurements in patients undergoing cardiac surgery. Thus, the present data question the reliability of transesophageal echo-Doppler derived cardiac output measurements in this setting and may have implications for using transesophageal echo-Doppler during goal-directed hemodynamic optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.

OBJECTIVE Continuous measurement of cardiac output (CCO) is of great importance in the critically ill. However, pulmonary artery thermodilution has been questioned for possible complications associated with right heart catheterization. Furthermore, measurements are delayed in the continuous mode during rapid hemodynamic changes. A new pulmonary artery catheter CCO device (Aortech, Bellshill, Sc...

متن کامل

Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.

BACKGROUND Cardiac output monitoring, as a part of a goal-directed haemodynamic management, has been shown to improve perioperative outcome in high-risk patients undergoing major surgical interventions. However, thorough validation of cardiac output monitoring devices in different clinical conditions is warranted. The aim of our study was to compare the reliability of a novel system for cardiac...

متن کامل

Measuring cardiac output during dobutamine infusion after off-pump coronary artery bypass: comparison of transesophageal echo-Doppler and thermodilution.

AIM To compare transesophageal echo-Doppler with thermodilution method for measuring cardiac output during dobutamine infusion after off-pump coronary artery bypass. METHOD Using transesophageal echo-Doppler and thermodilution methods, we measured cardiac output in 30 patients after off-pump coronary artery bypass, immediately before and 5, 15, and 30 min after the introduction of continuous ...

متن کامل

Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO). The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB). Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010