Asbestos amosite fibers were investigated to evaluate the damage caused by a transmission electron microscope (TEM) electron beam. Since elemental x-ray intensity ratios obtained by energy dispersive x-ray spectroscopy (EDS) are commonly used for asbestos identification, the impact of beam damage on these ratios was evaluated. It was determined that the magnesium/silicon ratio best represented the damage caused to the fiber. Various tests showed that most fibers have a current density threshold above which the chemical composition of the fiber is modified. The value of this threshold current density varied depending on the fiber, regardless of fiber diameter, and in some cases could not be determined. The existence of a threshold electron dose was also demonstrated. This value was dependent on the current density used and can be increased by providing a recovery period between exposures to the electron beam. This study also established that the electron beam current is directly related to the damage rate above a current density of 165 A/cm2. The large number of different results obtained suggest, that in order to ensure that the amosite fibers are not damaged, analysis should be conducted below a current density of 100 A/cm2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Asbestos Presence in a Factory that Produced Asbestos-Containing Products

In 2007, research was carried out to determine the type and amount of asbestos fibers in a Croatian factory with a long history of making asbestos-containing products.Since the 1970s, asbestos fibres have been considered carcinogenic in humans i.e as a known cancer-causing agent. In the environment, asbestos fibres are inactive and naturally resist biodegradation. In time, fibres can only be gr...

متن کامل

Airborne inorganic fibre level monitoring by transmission electron microscope (TEM): comparison of direct and indirect sample transfer methods.

The direct and indirect sample transfer techniques for measuring airborne inorganic fibres concentrations were studied by TEM for airborne rockwool fibres, chrysotile, amosite and tungsten oxide whiskers. The number and mass concentrations of fibres with aspect ratios > or = 5, prepared by these two techniques for fibres longer than 0.5 mu m and 5 mu m, and the aspect ratios were evaluated and ...

متن کامل

Relationship between lung asbestos fiber type and concentration and relative risk of mesothelioma. A case-control study.

Lung tissue from 221 definite and probable cases of malignant mesothelioma reported to the Australian Mesothelioma Surveillance Program from January 1980 through December 1985 and from an age-sex frequency matched control series of 359 postmortem cases were examined by light microscopic (LM) and analytical transmission electron microscopic (TEM) analysis and energy dispersive x-ray analysis (ED...

متن کامل

Electron microscopical investigation of asbestos fibers

Examination of asbestos fibers by electron microscopical techniques enables the observer to distinguish among the fiber types by morphological and structural characteristics. Chrysotile asbestos fibers are composed of bundles of fibrils. Fibers are often curvilinear with splayed ends. Individual fibrils consist of a central capillary defined by an electron dense crystalline wall. With increasin...

متن کامل

Comparison of the results of asbestos fibre dust counts in lung tissue obtained by analytical electron microscopy and light microscopy.

The efficiency of the light microscope with that of the electron microscope in detecting asbestos fibres in human lung tissue was computed. Necropsy material from 55 patients who had died from asbestos related diseases was analysed independently by phase contrast microscopy and electron microscopy. As expected the number of fibres identified using electron microscopy was higher than that identi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 13 12  شماره 

صفحات  -

تاریخ انتشار 2016