Determination of tartaric acid in wines by FIA with tubular tartrate-selective electrodes.
نویسندگان
چکیده
A flow injection analysis (FIA) system comprising a tartrate-(TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 microL into a phosphate buffer carrier (pH = 3.1; ionic strength 10(-2) mol/L) flowing at 3 mL/min, the slope was 58.06 +/- 0.6 with a lower limit of linear range of 5.0 x 10(-4) mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.
منابع مشابه
Simultaneous determination of tartaric acid and potassium in wines using a multicommuted flow system with dialysis.
A multicommuted flow system with the propulsion device placed before detection is proposed for the determination of tartaric acid and free potassium in table and Port wines. A dialysis unit was introduced to increase sample dilution and minimize matrix interferences. The determination of tartaric acid was based on the spectrophotometric monitorization of the complex formed by the dialyzed analy...
متن کاملDetermination of fluoride using ion-selective electrodes in the presence of aluminum.
We describe a method for determining fluoride with ion-selective electrodes (ISEs). Tartrate and Tris-based total ionic strength adjustment buffers (TISABs) were found to lower the interference from aluminum to a greater extent than conventional citrate-based TISABs. We adopted a solid TISAB addition method that is simple to perform, and can be carried out without lowering the level of fluoride...
متن کاملQuantitative Determination of Tartaric Acid in Tolterodine Tartrate by Ion Chromatography Using Conductivity Detection
The present paper deals with the development and validation of analytical method based on a single column high performance Ion chromatography with cation suppressed conductivity detection, developed for quantitation of tartaric acid. The diluent used for the preparation of sample solution was water and injected into a standard chromatographic system connected with 250mm length, 4.0 mm ID and 5....
متن کاملAutomatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detector
This paper describes the use of a FIA system for the automatic determination of uric acid in urine, using a tubular amperometric detector. In this system, glassy carbon electrodes of tubular configuration were activated by successive cyclical scans from 0.30 to 2.00 V versus Ag/AgCl reference electrode in 0.50 mol.L sulphuric acid solution. Samples were diluted in supporting electrolyte before ...
متن کاملL-tartaric acid synthesis from vitamin C in higher plants.
The biosynthetic pathway of L-tartaric acid, the form most commonly encountered in nature, and its catabolic ties to vitamin C, remain a challenge to plant scientists. Vitamin C and L-tartaric acid are plant-derived metabolites with intrinsic human value. In contrast to most fruits during development, grapes accumulate L-tartaric acid, which remains within the berry throughout ripening. Berry t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Fresenius' journal of analytical chemistry
دوره 369 5 شماره
صفحات -
تاریخ انتشار 2001