Benefits of dual chamber pacing in sick sinus syndrome.

نویسندگان

  • T Mitsuoka
  • R A Kenny
  • T A Yeung
  • S L Chan
  • J E Perrins
  • R Sutton
چکیده

The effects of DDD (fully automatic) and VVI (ventricular demand) pacing modes on exercise tolerance, symptom diary cards, and Holter monitoring were investigated in a randomised double blind crossover study of 16 patients who had had DDD pacemakers implanted because of frequent syncope. Eight patients presented with sick sinus syndrome and, with one exception, retrograde atrioventricular conduction and eight age and sex matched patients presented with 2:1 or complete atrioventricular block. Maximal symptom limited exercise in those with atrioventricular block was significantly higher after one month of DDD pacing than after VVI pacing. In those with sick sinus syndrome, however, maximal effort tolerance was not significantly different for the two pacing modes. In all but one patient with sick sinus syndrome sinus rhythm developed during exercise in VVI pacing. For both VVI and DDD modes maximal atrial rates were significantly lower in those with sick sinus syndrome. Palpitation and general wellbeing were significantly improved during DDD pacing in the eight patients with sick sinus syndrome. Shortness of breath was improved by DDD pacing in the eight patients with atrioventricular block but not in those with sick sinus syndrome. Holter monitoring showed that sick sinus syndrome patients remained in paced rhythm, either DDD or VVI, for most of the 24 hour period. DDD pacing was better than VVI pacing in sick sinus syndrome with retrograde atrioventricular conduction. Despite their ability to show sinus rhythm and inhibit their pacemakers on exercise patients with sick sinus syndrome are just as likely to have symptomatic benefit from DDD pacing as patients with atrioventricular block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of dual-chamber pacing compared with ventricular pacing for sinus node dysfunction.

BACKGROUND Compared with single-chamber ventricular pacing, dual-chamber pacing can reduce adverse events and, as a result, improve quality of life in patients paced for sick sinus syndrome. It is not clear, however, how these benefits compare with the increased cost of dual-chamber pacemakers. METHODS AND RESULTS We used 4-year data from a 2010-patient, randomized trial to estimate the incre...

متن کامل

Single-lead ventricular pacing is no longer an option for sick sinus syndrome.

n this issue of the Journal, Link et al. (1) report a study on he occurrence of pacemaker syndrome in the Mode Selecion (MOST) trial. The MOST trial is the largest randomzed trial of pacing mode selection in patients with sick sinus yndrome (SSS), including a total of 2,010 patients who all eceived rate-adaptive atrioventricular synchronous dualhamber pacing (DDDR) pacemakers and were randomly ...

متن کامل

[The use of auto mode switching in patients with sick sinus syndrome].

BACKGROUND At present the dual chamber pacing, originally developed for patients with AV blockades, is widely used also for patients with Sick sinus syndrome (tachycardic-bradycardic type). But these patients often cause therapeutical problems to their physicians. In these cases either antiarrhythmic therapy is necessary to prevent recurrent supraventricular tachycardias (which are cause of rap...

متن کامل

A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome.

AIMS In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any difference between single-lead atrial pacing (AAIR) and dual-chamber pacing (DDDR). METHODS A...

متن کامل

Who Needs Physiologic Pacing and Why?

Various pacing technologies have been developed during the past 50 years since the first pacemaker was implanted in 1958. Dual-chamber pacing, rate responsiveness, programmable and rate-responsive atrioventricular (AV) intervals, alternative-site pa0cing, and new multichamber pacing devices are all attempts to mimic normal cardiac physiology as much as feasible. The categories of alternative-si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 1988