First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements
نویسندگان
چکیده
The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allows continuous acquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operate continuously in the microsecond time frame, while at the same time probing longer timescales.
منابع مشابه
Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods
High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملIntroducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues
Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...
متن کاملThe feasibility of using microstrip gas detector as radon detector for earthquake prediction
In the last decade, several studies have concluded that elevated concentrations of radon gas in soil or groundwater could be the sign of an imminent earthquake. It is believed that in case of sudden movement of rocks before earthquake, radon is released from the depth of ground and reached the surface. In this way, by measuring Radon concentration change, earthquake prediction is possible. In t...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کامل