A handheld open-field infant keratometer (an american ophthalmological society thesis).
نویسنده
چکیده
PURPOSE To design and evaluate a new infant keratometer that incorporates an unobstructed view of the infant with both eyes (open-field design). METHODS The design of the open-field infant keratometer is presented, and details of its construction are given. The design incorporates a single-ring keratoscope for measurement of corneal astigmatism over a 4-mm region of the cornea and includes a rectangular grid target concentric within the ring to allow for the study of higher-order aberrations of the eye. In order to calibrate the lens and imaging system, a novel telecentric test object was constructed and used. The system was bench calibrated against steel ball bearings of known dimensions and evaluated for accuracy while being used in handheld mode in a group of 16 adult cooperative subjects. It was then evaluated for testability in a group of 10 infants and toddlers. RESULTS Results indicate that while the device achieved the goal of creating an open-field instrument containing a single-ring keratoscope with a concentric grid array for the study of higher-order aberrations, additional work is required to establish better control of the vertex distance. CONCLUSION The handheld open-field infant keratometer demonstrates testability suitable for the study of infant corneal astigmatism. Use of collimated light sources in future iterations of the design must be incorporated in order to achieve the accuracy required for clinical investigation.
منابع مشابه
Sources of binocular suprathreshold visual field loss in a cohort of older women being followed for risk of falls (an American Ophthalmological Society thesis).
PURPOSE To determine the sources of binocular visual field loss most strongly associated with falls in a cohort of older women. METHODS In the Study of Osteoporotic Fractures, women with severe binocular visual field loss had an increased risk of two or more falls during the 12 months following the eye examination. The lens and fundus photographs of the 422 women with severe binocular visual ...
متن کاملThe blue arc entoptic phenomenon in glaucoma (an American ophthalmological thesis).
PURPOSE To determine whether the blue arc entoptic phenomenon, a positive visual response originating from the retina with a shape that conforms to the topology of the nerve fiber layer, is depressed in glaucoma. METHODS We recruited a cross-sectional, nonconsecutive sample of 202 patients from a single institution in a prospective manner. Subjects underwent full ophthalmic examination, inclu...
متن کاملCausing and curing infantile esotropia in primates: the role of decorrelated binocular input (an American Ophthalmological Society thesis).
PURPOSE Human infants at greatest risk for esotropia are those who suffer cerebral insults that could decorrelate signals from the 2 eyes during an early critical period of binocular, visuomotor development. The author reared normal infant monkeys, under conditions of binocular decorrelation, to determine if this alone was sufficient to cause esotropia and associated behavioral as well as neuro...
متن کاملSpectral domain optical coherence tomography in glaucoma: qualitative and quantitative analysis of the optic nerve head and retinal nerve fiber layer (an AOS thesis).
PURPOSE To demonstrate that video-rate spectral domain optical coherence tomography (SDOCT) can qualitatively and quantitatively evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) glaucomatous structural changes. To correlate quantitative SDOCT parameters with disc photography and visual fields. METHODS SDOCT images from 4 glaucoma eyes (4 patients) with varying stages of op...
متن کاملCarrier frequency of CYP1B1 mutations in the United States (an American Ophthalmological Society thesis).
PURPOSE CYP1B1 mutations cause autosomal recessive congenital glaucoma. Disease risk assessment for families with CYP1B1 mutations requires knowledge of the population mutation carrier frequency. The purpose of this study is to determine the CYP1B1 mutation carrier frequency in clinically normal individuals residing in the United States. Because CYP1B1 mutations can exhibit variable expressivit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Transactions of the American Ophthalmological Society
دوره 108 شماره
صفحات -
تاریخ انتشار 2010