Determination of quadrupole parameters with a composite pulse for spurious signal suppression.

نویسندگان

  • Y Millot
  • P P Man
چکیده

Spurious signals such as the piezoelectric signal from a ferroelectric crystal or the ringing signal from the NMR probe head tuned for low gyromagnetic ratio nuclei are often observed in pulsed NMR. Both signals are cancelled using the Hahn echo sequence with appropriate phase cyclings. The present paper applies a composite-pulse sequence to cancel the ringing signal. The main advantage of this sequence over the Hahn echo sequence is in the simplicity of optimizing the line intensity: the optimization of only one pulse duration for this sequence but of two pulse durations and the interpulse delay for the Hahn echo sequence. We are interested in half-integer quadrupole spins (I = 3/2, 5/2, 7/2, and 9/2), which means that we must consider the first-order quadrupole interaction during the pulses. For simplicity, we deal mainly with spin I = 3/2 nuclei. Since the central-line intensity depends on the ratio of the quadrupole coupling constant (QCC) to the amplitude of the RF pulse, we can determine the QCC from a featureless lineshape by fitting the variation of the experimental central-line intensity for increasing pulse duration with theoretical results. Contrary to the one-pulse sequence where the central-line intensity is proportional to the pulse duration if the latter is short, there is no such condition with the composite-pulse sequence. In other words, this sequence does not allow us to quantify the relative spin populations in powders. The size of the sample must be much smaller than that of the RF coil in order for the RF magnetic field to become homogeneous for the sample. We used (87)Rb (I = 3/2) in an aqueous solution of RbCl and in RbNb2O5F powder, (131)Xe (I = 3/2) of xenon gas physisorbed in Na-Y zeolite, and (23)Na (I = 3/2) in two well-known powders (NaNO3 and NaNO2) to support our theoretical result.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-Active Pulse-Switching SSDC Vibration Suppression using Magnetostrictive Materials

One of the best vibration control methods using smart actuators are semi-active approaches which are as strong as active methods and need no external energy supply such as passive ones. Compared with piezoelectric-based, magnetostrictive-based control methods have higher coupling efficiency, higher Curie temperature, higher flexibility to be integrated with curved structures and no depolarizati...

متن کامل

COLUMN PRECONCENTRATION OF URANIUM BY 1 -(2-PY RIDYLAZ0)-2-NAPHTHOL SUPPORTED ON NAPHTHALENE USING DIF'FERENTLAL PULSE POLAROGRAPHY

A solid chelating material, 1-(2-pyridy1azo)-2-naphthol (PAN) supported on naphthalene provides a rapid and highly selective means of preconcentration of uranium from aqueous solution. Uranium is quantitatively retained on this adsorbent in the pH range 9.8-10.7 with a flow rate of 1 ml min . The metal complex was desorbed with 10 ml of 2 M hydrochloric acid and uranium is determined by d...

متن کامل

Spurious Response Suppression in Waveguide Filters using E-Shaped Chiral Resonators

In this paper, chiral E-shaped resonators are used in a waveguide. Direction of EM wave and position of resonators for effective excitation is studied and various resonances of E-shaped resonators are determined. As a consequence an analytical equivalent circuit model is proposed. Finally, an array of these resonators is used to realize a wide reject band. The resulted band stop filter performa...

متن کامل

Simultaneous Determination of Traces of Lead and Cadmium in Various Samples by Differential Pulse Polarography after Adsorbing Their 1-(2-Pyridyazol)-2-Naphthol onto Microcrystalline Naphthalene

A highly selective, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of cadmium and lead present together in various standard alloys and biological samples after adsorption of their 1-(2-pyridylazo)-2-naphthol complexes on microcrystalline naphthalene. Cadmium and lead complexes are equantitatively adsorbed on microcrysta...

متن کامل

A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination

Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 150 1  شماره 

صفحات  -

تاریخ انتشار 2001