Measurement of Field Distortion in Free-Air Ionization Chambers
نویسنده
چکیده
A two dimensional allaJog of a free-air ionization chamber for the measurement of fi eld distortion was obtained by painting conducting lines on resistance paper to represent cross sections of the electrodes. Guard wires were simulated by driving record p layer needles into the paper . The volume of the chamber from which charge was collected was related to the resistance between two of the lines on the paper, and small changes in this volume could be determined accurately by observing resistance changes. Grounded plates external to the chamber were simulated by additional lines painted on the paper, and the effect of t hese plates on the collecting volume was determined by measuring a change in res istance as the potential of these (simulated) external plates was changed. M easurements were also made for gnards in the form of double wires and strips. There is some evidence from m easurements on three dimensional ionization chambers that the top and bottom of t he surrounding grounded X-ray shield tends to decrease the effects of distortion caused by the ends of the X-ray shield, so that the data obtained here would represent an upper limit to the error for the indicated chamber cross section.
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملInterpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملFabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...
متن کامل