Parametric Study of Charging Inlet Diffuser Performance in Stratified Chilled Water Storage Tanks with Radial Diffusers: Part 1–Model Development and Validation

نویسنده

  • A. Musser
چکیده

A computational fluid dynamics (CFD) model has been developed to simulate the flow and heat transfer near a lower radial inlet diffuser in a cylindrical stratified chilled water storage tank during charging. The model was used to perform parametric simulations of inlet diffuser performance in full-scale tanks during thermocline formation, from which first-order correlation relating thermal performance to tank and diffuser design parameters were derived. Part 1 describes the development of the CFD model and its validation. Part 2 reports the results of the parametric study. The two-dimensional, transient model was implemented in a commercial finite element code. The model has been validated with field-measured data from two full-scale tanks. Laminar analysis predicted field-measured temperature profiles well, even under ostensibly transitional conditions, provided that variations in inlet temperature during the field tests were accurately modeled. These results suggest that turbulence has a secondary effect on the development of thermoclines within the range of parameters considered and that laminar models may be useful for modeling performance of full-scale tanks over a wide range of inlet parameters. The fully developed temperature profile was found to be insensitive to the velocity distribution assumed at the inlet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parametric Study of Charging Inlet Diffuser Performance in Stratified Chilled Water Storage Tanks with Radial Diffusers: Part 2–Dimensional Analysis, Parametric Simulations and Simplified Model Development

A parametric study of the thermal performance during charging of a full-scale radial inlet diffuser in a cylindrical stratified chilled water storage tank was performed by applying factorial experimental theory to the results of simulations performed with a validated computational fluid dynamics (CFD) model. Part 1 describes the development and validation of the CFD model. Part 2 summarizes the...

متن کامل

Measured and Modeled Charging of a Stratified Chilled Water Thermal Storage Tank with Slotted Pipe Diffusers

As part of ASHRAE Research Project 1185, field data from the constant flow rate charging of a stratified chilled water storage tank with double-ring octagonal slotted-pipe diffusers serving a university chilled water system were compared with results of a transient axisymmetric computational fluid dynamics (CFD) model. Charge processes at flows near design flow rate and 50% of design were model...

متن کامل

Performance Evaluation of A Stratified Chilled- Water Thermal Storage System

In countries with hot climates, air-conditioning forms a large proportion of annual peak electrical demand, requiring expansion of power plants to meet the peak demand, which goes unused most of the time. Use of well-designed cool storage can offset the peak demand to a large extent. In this study, an air conditioning system with naturally stratified storage tank was designed, constructed and t...

متن کامل

Modeling and Experimental Validation of Area Constrained Ice Storage Systems

J.E. Braun, Ph. D., P.E. Purdue University This paper describes the development and validation of an improved mechanistic model for predicting the thermal performance of an area constrained ice storage system. Experimental data was obtained from a fully instrumented thermal storage test cell located within the Herrick Laboratories, Purdue University. Results for both charging and discharging cy...

متن کامل

Parametric studies on thermally strati®ed chilled water storage systems

An analysis of the strati®cation decay in thermally strati®ed vertical cylindrical cool storage systems is presented using a one dimensional conjugate heat conduction model. The degree of thermal strati®cation depends upon the length to diameter ratio, wall thickness to length ratio, the thermo-physical properties of the material of the storage tank, the type and thickness of the insulation and...