Respiratory resistance by impulse oscillometry in healthy Iranian children aged 5-19 years.

نویسندگان

  • Babak Amra
  • Froogh Soltaninejad
  • Mohammad Golshan
چکیده

The impulse oscillation system (IOS) measures respiratory impedance (Zrs) in terms of resistance (Rrs) and reactance (Xrs) at multiples of 5 Hz. These measurements can be used clinically to help diagnose and monitor respiratory disorders, independent of effort. There is, as yet, no information on reference values for IOS in Iranian adolescents.The predictive equation for resistance and impedance at 5 and 15 and 25 Hz, for the first time, in 509 Iranian adolescent subjects (265 boys (aged 6-19 years) and 253 girls (aged 5-19 years) were determined. Gender-specific linear prediction equations were developed by multiple regression analysis; with measuring (R5, R15, R25, X5, X15, X 25) as dependent variables regressed against age (A) and height (H).For both genders, age and height had negative effects on resistance, while age and height had a positive effect on reactance. The prediction equations for R5 and X5 are as follows: R5: -1.35x10(-5) x agex2.823 - 0.001 x height x1.022 + 0.547 for girlsX5: 1.78x10(-7)x age x1.08 + 0.002 height x4.150 - 0.539, for girls R5: -6.19x10(-7)x age x 3.820 - 6.78E-005 x height x1.651 + 0.691 for boysX5: 6.95x10(-23) x age x16.226 + 0.004 height x 0.846- 0.430, for boys, respectively. Our results therefore provide an original frame of reference for R5, R15, R25, X5, X15, X25 in Iranian adolescents population, obtained from a standardized forced oscillation technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years.

The forced oscillation technique makes it possible to evaluate the mechanical properties of the respiratory system with a minimum of cooperation. The method is therefore especially useful in children. Impulse oscillometry (IOS) is a commercially available version of this technique. There is, as yet, limited information on reference values for IOS in children. The aim of this study was to extend...

متن کامل

Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children

PURPOSE The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool...

متن کامل

Impulse oscillometry, spirometry, and passive smoking in healthy children and adolescents.

OBJECTIVE To identify changes in the forced and quiet breathing parameters of lung function in healthy children and adolescents exposed to passive smoking (PS). METHOD Comparative cross-sectional study. Healthy schoolchildren aged 6 to 14 years. We collected anthropometric data, lung function parameters using spirometry (forced breathing), and quiet breathing parameters using impulse oscillom...

متن کامل

Evaluation of pulmonary functions in preschool children born late-preterm.

AIM The aim of this study was to evaluate the pulmonary functions of preschool children born late-preterm. MATERIAL AND METHODS Children aged between 3-7 years who were born at 340/7-366/7 weeks' gestation represented the target sample. Patients with a diagnosis of congenital cardiac, pulmonary and/or muscle diseases were excluded. Respiratory symptoms were evaluated using the modified asthma...

متن کامل

Reference values for Japanese children's respiratory resistance using the LMS method.

BACKGROUND The forced oscillation technique (FOT) is useful for studying pulmonary function in children, as well as in school children with asthma. However, the standard values for respiratory resistance (Rrs) in Asian school children remain unknown. We evaluated the standard Rrs using a type of FOT, impulse oscillometry (IOS), in healthy Japanese children at elementary and junior high schools....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Iranian journal of allergy, asthma, and immunology

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2008