Spatial contrast sensitivity in dynamic and static additive luminance noise

نویسندگان

  • J. Jason McAnany
  • Kenneth R. Alexander
چکیده

The purpose of this study was to define the quantitative relationship between the temporal characteristics of additive luminance noise and the properties of the spatial contrast sensitivity function (CSF). CSFs were obtained from two observers using Gabor patch targets of short duration that were added to white luminance noise with a range of root-mean-square contrasts (c(rms)). The noise was either dynamic or static and was either of the same duration as the test target (synchronous) or of longer duration (asynchronous). For targets presented in asynchronous dynamic, synchronous dynamic, and synchronous static noise, the CSFs became increasingly band-pass with increasing c(rms), whereas the CSFs were low-pass at all levels of c(rms) for targets presented in asynchronous static noise. For all noise types, the properties of the CSFs were well-predicted by the linear amplifier model (LAM), in which the signal energy at threshold (E(t)) is related linearly to noise spectral density (N). The fundamentally different characteristics of CSFs obtained in asynchronous static noise can be accounted for by a previous proposal that this noise type biases contrast sensitivity toward transient (inferred magnocellular) mechanisms. The other three modes of noise presentation appear to emphasize detection by sustained (inferred parvocellular) mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast thresholds in additive luminance noise: Effect of noise temporal characteristics

This study investigated the way in which the temporal properties of additive luminance noise influence threshold contrast and affect estimates of equivalent noise and sampling efficiency. Threshold contrast was obtained from four visually normal observers for a 2-cycle-per-degree Gabor patch across a range of target durations in the absence and presence of additive luminance noise that was eith...

متن کامل

Temporal properties of the visual responses to luminance and contrast modulated noise

Vision is sensitive to first-order luminance modulations and second-order modulations of carrier contrast. Our knowledge of the temporal properties of second-order vision is insufficient and contradictory. Using temporal summation and reaction time paradigms, we found that the type of visual noise (static or dynamic) determines the temporal properties of the responses to luminance and contrast ...

متن کامل

The influence of spatial and temporal noise on the detection of first-order and second-order orientation and motion direction

Thresholds for identifying the direction of second-order motion (contrast-modulated dynamic noise) are consistently higher than those for identifying spatial orientation, unlike first-order gratings for which the two thresholds are typically the same. Two explanations of this phenomenon have been proposed: either first-order and second-order patterns are encoded by separate mechanisms with diff...

متن کامل

Perception of motion direction in luminance-and contrast-defined reversed-phi motion sequences

Nonlinear processing can be used to recover the motion of contrast modulations of binary noise patterns. A nonlinear stage has also been proposed to explain the perception of forward motion in motion sequences which typically elicit reversed-phi. We examined perceived direction of motion for stimuli in which these reversed motion sequences were used to modulate the contrast of binary noise patt...

متن کامل

Luminance noise as a novel approach for measuring contrast sensitivity within the magnocellular and parvocellular pathways

This study evaluated the extent to which different types of luminance noise can be used to target selectively the inferred magnocellular (MC) and parvocellular (PC) visual pathways. Letter contrast sensitivity (CS) was measured for three visually normal subjects for letters of different size (0.8°-5.3°) under established paradigms intended to target the MC pathway (steady-pedestal paradigm) and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2010