A general purpose cold finger using a vibration-free mounted He closed-cycle cryostata)

نویسندگان

  • P. Boolchand
  • G. H. Lemon
  • W. J. Bresser
چکیده

A method for mounting a He closed-cycle cryostat which consists of an exchange gas envelope around the cold head to cool an independently supported sample mount as in model DE202 with a DMX-20 interface from APD Cryogenics, Inc. is described. No detectable vibration of the sample mount is observed as evaluated using 57Fe Mossbauer spectroscopy and a piezoelectric accelerometer. Using a 25 ,um thick a+Fe foil a linewidth of 0.231(3) mm/s at 300 K with the refrigerator on and the same linewidth with the refrigerator off is observed. The easy optical access afforded by such a cold finger makes it an economical general purpose laboratory tool for performing low-T spectroscopic investigations, such as microwave, optical, yray, x-ray and neutron-scattering measurements. Other applications include electrical transport, SIMS, RBS, and rare-gas matrix isolation. Q 1995 American Ins&z&e of Physics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش یک مورد نادر آسیب بسته تاندون‌های فلکسور عمقی

     Introduction: The usual causes of flexor tendon injuries in hand are penetrating wounds. Closed injury and avulsion of flexor tendon are rare and mostly occur as avulsion of flexor digitorum profundus tendon of ring finger from its bony insertion at distal phalanx. Closed avulsion of flexor digitorum superficialis is even rarer. The rarest is simultaneous closed avulsion of both flexors in...

متن کامل

گزارش یک مورد آسیب بسته تاندونهای فلکسور عمقی و سطحی انگشت حلقه

Introduction: The usual causes of flexor tendon injuries in hand are penetrating wounds. Closed injury and avulsion of flexor tendon are rare and mostly occur as avulsion of flexor digitorum profundus tendon of ring finger from its bony insertion at distal phalanx. Closed avulsion of flexor digitorum superficialis is even rarer. The rarest is closed and simultaneous avulsion of both flexors i...

متن کامل

A CLOSED FORM SOLUTION FOR FREE VIBRATION ANALYSIS OF TUBE-IN-TUBE SYSTEMS IN TALL BUILDINGS

In this paper the dynamic response of tube-in-tube systems for tall building structures is investigated. Inner and outer tubes are modeled using equivalent continuous orthotropic membranes; in which, each tube is individually modeled by a cantilever box beam. By applying the compatibility conditions on deformation of the two tubes, the governing dynamic equations of the tube-in-tube structure a...

متن کامل

40 K Liquid Neon Energy Storage Unit

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to suddenly incoming heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy s...

متن کامل

Free Vibration Analysis of a Sloping-frame: Closed-form Solution versus Finite Element Solution and Modification of the Characteristic Matrices (TECHNICAL NOTE)

This article deals with the free vibration analysis and determination of the seismic parameters of a sloping-frame which consists of three members; a horizontal, a vertical, and an inclined member. The both ends of the frame are clamped, and the members are rigidly connected at joint points. The individual members of the frame are assumed to be governed by the transverse vibration theory of an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999