Calibration Method for Determining the Physical Location of the Ultrasound Image Plane

نویسندگان

  • Devin V. Amin
  • Takeo Kanade
  • Branislav Jaramaz
  • Anthony M. DiGioia
  • Constantinos Nikou
  • Richard S. LaBarca
  • James E. Moody
چکیده

This paper describes a calibration method for determining the physical location of the ultrasound (US) image plane relative to a rigidly attached 3D position sensor. A calibrated US probe can measure the 3D spatial location of anatomic structures relative to a global coordinate system. The calibration is performed by aiming the US probe at a calibration target containing a known point (1 mm diameter sphere) in physical space. This point is repeatedly collected at various locations in the US image plane to produce the calibration dataset. An idealized model of the collection process is used to eliminate outliers from the calibration dataset and also to examine the theoretical accuracy limits of this method. The results demonstrate accurate and robust calibration of the 3D spatial relationship between the US image plane and the 3D position sensor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A fully automatic calibration procedure for freehand 3D ultrasound

This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the c...

متن کامل

Fetal gender prediction based on placental location throughout first trimester transabdominal ultrasound

Background: Awareness of fetal gender at primary stages of pregnancy is very important. Fetal sex determination can reveal pressing information regarding fetal health. One of the methods of determining gender in the first trimester is according to the location of placenta. . This study investigated the accuracy and sensitivity of this method with trans-abdominal ultrasound in determining the se...

متن کامل

Immediate Ultrasound Calibration with Three Poses and Minimal Image Processing

This paper introduces a novel method for ultrasound (US) probe calibration based on closed-form formulation and using minimal US imaging allowing for an immediate result. Prior to calibration, a position sensor is used to track each image in 3D space while the US image is used to determine target location within the image. The calibration procedure uses these two pieces of information to determ...

متن کامل

An Efficient Platform for Freehand US Calibration

Freehand three-dimensional ultrasound system allows intra-operative imaging of pathologic tissue for image-guided injection. Accurate registration of ultrasound image for injection navigation requires calibration that is timeconsuming and tedious. We present an efficient calibration system based on a clinical injector. The injector equipped with an optical tracking sensor is moved in the vicini...

متن کامل

An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001