Clinical applicability of functional hemodynamic monitoring
نویسندگان
چکیده
Recent interest in functional hemodynamic monitoring for the bedside assessment of cardiovascular insufficiency has heightened. Functional hemodynamic monitoring is the assessment of the dynamic interactions of hemodynamic variables in response to a defined perturbation. Accordingly, fluid responsiveness can be predicted in a quantities fashion by measuring as arterial pulse pressure variation and left ventricular stroke volume variation during positive pressure breathing or the change in cardiac output response to a passive leg raising maneuver. However, volume responsiveness, though important, reflects only part of the overall spectrum of functional physiological variables that can be measured to define physiologic state and monitor response to therapy. Dynamic tissue O2 saturation (StO2) responses to complete stop flow conditions, which can be created by measuring hand StO2 and occluding flow with a blood pressure cuff, assesses cardiovascular sufficiency and microcirculatory blood flow distribution. Furthermore, these measures can be made increasingly more sensitive and specific if coupled to other "traditional" measures of organ perfusion, such as blood lactate levels.
منابع مشابه
مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری
Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...
متن کاملEvaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring
Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...
متن کاملHemodynamic response magnetic resonance imaging: application for renal hemodynamic characterization.
BACKGROUND The clinical use of iodinated radiocontrast agents or gadolinium for renal perfusion imaging is limited in the presence of renal dysfunction. We have previously demonstrated the feasibility of hemodynamic response imaging (HRI), a functional magnetic resonance imaging (MRI) method combined with hypercapnia and hypercapnic-hyperoxia, for monitoring changes in liver perfusion and hemod...
متن کاملClinical review: Does it matter which hemodynamic monitoring system is used?
Hemodynamic monitoring and management has greatly improved during the past decade. Technologies have evolved from very invasive to non-invasive, and the philosophy has shifted from a static approach to a functional approach. However, despite these major changes, the critical care community still has potential to improve its ability to adopt the most modern standards of research methodology in o...
متن کاملOptimizing Cardiac Out-Put to Increase Cerebral Penumbral Perfusion in Large Middle Cerebral Artery Ischemic Lesion—OPTIMAL Study
INTRODUCTION In unsuccessful vessel recanalization, clinical outcome of acute stroke patients depends on early improvement of penumbral perfusion. So far, mean arterial blood pressure (MAP) is the target hemodynamic parameter. However, the correlations of MAP to cardiac output (CO) and cerebral perfusion are volume state dependent. In severe subarachnoid hemorrhage, optimizing CO leads to a red...
متن کامل