Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes
نویسندگان
چکیده
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stopping power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeter is applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter concept. Data from the AGORFIRM beamline at KVI Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. High energy protons traversing the detector leave a track through the sensor layers. These tracks are spread out though charge diffusion processes. A charge diffusion model is applied for acquisition of estimates of the deposited energy of the protons in each sensor layer by using the size of the charge diffused area. A model fit of the Bragg Curve is applied to each reconstructed track and through this, estimating the residual range of each proton. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.
منابع مشابه
A New Maximum Power Point Tracking Method for PEM Fuel Cells Based On Water Cycle Algorithm
Maximum Power Point (MPP) tracker has an important role in the performance of fuel cell (FC) systems improvement. Tow parameters which have effect on the Fuel cell output power are temperature and membrane water. So contents make the MPP change by with variations in each parameter. In this paper, a new maximum power point tracking (MPPT) method for Proton Exchange Membrane (PEM) fuel cell is pr...
متن کاملOptimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy
The purposes of this study were to optimize a proton computed tomography system (pCT) for proton range verification and to confirm the pCT image reconstruction algorithm based on projection images generated with optimized parameters. For this purpose, we developed a new pCT scanner using the Geometry and Tracking (GEANT) 4.9.6 simulation toolkit. GEANT4 simulations were performed to optimize th...
متن کاملOptimized Digital Optical Switch Using Proton Exchanged Lithium Niobate Waveguides
The main emphasis in developing DOS has been on achieving low crosstalk (CT). CT in the order of -30 dB is acceptable in conventional DOS and below that value is hard to achieve. Relatively low drive voltage (or power requirements) is also necessary to optimized DOS. This paper depicts the design of Y-branched digital optical switches (DOS) with optimized on-chip area coverage, reduced driving ...
متن کاملCALET measurements with cosmic nuclei: expected performances of tracking and charge identification
CALET is a space mission currently in the final phase of preparation for a launch to the International Space Station (ISS), where it will be installed on the Exposed Facility of the Japanese Experiment Module (JEM-EF). In addition to high precision measurements of the electron spectrum, CALET will also perform long exposure observations of cosmic nuclei from proton to iron and will detect trans...
متن کاملDose distribution of protons and flux of secondary particles in breast proton therapy.
Introduction: Proton therapy is newer therapeutic method for early stage breast cancer. Proton beams release most of their energy in the Bragg peak and then will be a rapid decline in their end. When protons interact with matter, produce secondary particles like neutrons and gammas, and these unwanted radiation has no beneficial effect and also is believed to increase the risk ...
متن کامل