Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh

نویسندگان

  • James M. Massullo
  • Tejinder P. Singh
  • Ward J. Dunnican
  • Brian R. Binetti
چکیده

BACKGROUND Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. METHODS Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. RESULTS Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. CONCLUSIONS In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Repair of Giant Type IV Hiatal Hernia

In this case report, we described a 74-year-old female patient with major complaint of respiratory problemsdyspnea after meal. Chest X-ray of the patient revealed a  gianttype IV hiatal hernia. Preoperative evaluations of the patient included esophagoscopy, esophageal manometry, barium swallow, and CT-scan. Repair of the hernia was performed using a dual mesh on the diaphragm and partial anteri...

متن کامل

Laparoscopic Hiatal Hernia Repair in 221 Patients: Outcomes and Experience.

BACKGROUND AND OBJECTIVES Hiatal hernia is a common condition often associated with symptomatic gastroesophageal reflux disease (GERD). The objectives of this study were to examine the efficacy and safety of laparoscopic hiatal hernia repair (LHHR) with biologic mesh to reduce and/or alleviate GERD symptoms and associated hiatal hernia recurrence. METHODS We retrospectively reviewed consecuti...

متن کامل

The Use of Biological Meshes in Diaphragmatic Defects – An Evidence-Based Review of the Literature

The widespread use of meshes for hiatal hernia repair has emerged in the era of laparoscopic surgery, although sporadic cases of mesh augmentation of traumatic diaphragmatic rupture have been reported. The indications for biologic meshes in diaphragmatic repair are ill defined. This systematic review aims to investigate the available evidence on the role of biologic meshes in diaphragmatic rupt...

متن کامل

Prosthetic Bioabsorbable Mesh for Hiatal Hernia Repair During Sleeve Gastrectomy

BACKGROUND AND OBJECTIVES Laparoscopic sleeve gastrectomy has become a valuable primary bariatric operation. It has an acceptable complication profile and amount of weight loss. However, one of the most distressing complications to the patient is reflux postoperatively. There is thought to be a relationship between a hiatal hernia and postoperative reflux. There is disagreement on how to addres...

متن کامل

Cardiac complications after laparoscopic large hiatal hernia repair. Is it related with staple fixation of the mesh? -Report of three cases

INTRODUCTION Laparoscopic Nissen operation with mesh reinforcement remains being the most popular operation for large hiatal hernia repair. Complications related to mesh placement have been widely described. Cardiac complications are rare, but have a fatal outcome if they are misdiagnosed. PRESENTATION OF CASES We sought to outline our institutional experience of three patients who developed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2012