4pi-microscopy with 1-photon Excitation

نویسندگان

  • Jörg Bewersdorf
  • Hilmar Gugel
  • Roman Schmidt
  • Stefan W. Hell
چکیده

Over the last years two-photon excitation 4Pi-microscopy with an axial resolution of ~100 nm has been demonstrated in multiple biological applications [1-3]. The artefact-free presentation of the recorded structures has been possible because of the contiguous optical transfer function (OTF), which allows reliable image deconvolution. The use of two-photon excitation (2PE) has been critical to suppress the artefact-producing side-lobes of the 4Pi-point spread function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

4Pi microscopy of type A with 1-photon excitation in biological fluorescence imaging.

We demonstrate that oil immersion lenses with a semi-aperture angle >/= 74 degrees enable 4Pi confocal fluorescence microscopy of type A with 1 photon excitation. The axial sidelobes amount to < 50 % of the main diffraction maximum, implying that lobe induced artifacts can be removed from the image data. The advancement reported herein enables a relative inexpensive implementation of 4Pi micros...

متن کامل

Image formation and data acquisition in a stage scanning 4Pi confocal fluorescence microscope.

We describe the three-dimensional (3-D) image formation and data acquisition in a stage scanning 4Pi confocal fluorescence microscope with the use of two-photon excitation. The 3-D point-spread functions of the 4Pi confocal and regular confocal microscope are measured and compared. Particular emphasis is given to the data acquisition procedure. 4Pi confocal microscopy results in a point-spread ...

متن کامل

Cooperative 4Pi excitation and detection yields sevenfold sharper optical sections in live-cell microscopy.

Although the addition of just the excitation light field at the focus, or of just the fluorescence field at the detector is sufficient for a three- to fivefold resolution increase in 4Pi-fluorescence microscopy, substantial improvements of its optical properties are achieved by exploiting both effects simultaneously. They encompass not only an additional expansion of the optical bandwidth, but ...

متن کامل

Fundamental improvement of resolution with a 4Pi-confocal fluorescence microscope using two-photon excitation

A new type of confocal fluorescence microscope with an unprecedented resolution is proposed. Calculations demonstrate that an axial resolution on the order of 100 nm can be achieved in a confocal microscope with enlarged aperture when two-photon excitation is applied. This axial resolution is up to four times higher than that ofa confocal fluorescence microscope. The proposed microscope yields ...

متن کامل

Increasing the Lateral Resolution in Confocal Fluorescence and Bio-luminescence Microscopes

Improving the spatial resolution in optical microscopes is a challenging task for many applications. In fluorescence confocal microscopy, the resolution is given by the Detection Efficiency Function (DEF) resulting from the product of the Excitation Efficiency Function (EEF) by the Collection Efficiency Function (CEF). The focalisation of the pump laser beam by a high numerical aperture objecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005