Measurements of the linac coherent light source laser heater and its impact on the x-ray free-electron laser performance

نویسندگان

  • Z. Huang
  • A. Brachmann
  • F.-J. Decker
  • Y. Ding
  • D. Dowell
  • P. Emma
  • J. Frisch
  • S. Gilevich
  • G. Hays
  • Ph. Hering
  • R. Iverson
  • H. Loos
  • A. Miahnahri
  • H.-D. Nuhn
  • D. Ratner
  • G. Stupakov
  • J. Turner
  • J. Welch
  • W.White
  • J. Wu
  • D. Xiang
چکیده

The very bright electron beam required for an x-ray free-electron laser (FEL), such as the linac coherent light source (LCLS), is susceptible to a microbunching instability in the magnetic bunch compressors, prior to the FEL undulator. The uncorrelated electron energy spread in the LCLS can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the FEL performance. To this end, a ‘‘laser-heater’’ system has been installed in the LCLS injector, which modulates the energy of a 135-MeV electron bunch with an IR-laser beam in a short undulator, enclosed within a four-dipole chicane. In this paper, we report detailed measurements of laser-heater-induced energy spread, including the unexpected self-heating phenomenon when the laser energy is very low. We discuss the suppression of the microbunching instability with the laser heater and its impact on the x-ray FEL performance. We also present the analysis of these experimental results and develop a threedimensional longitudinal space charge model to explain the self-heating effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Focus characterization at an X-ray free-electron laser by coherent scattering and speckle analysis

X-ray focus optimization and characterization based on coherent scattering and quantitative speckle size measurements was demonstrated at the Linac Coherent Light Source. Its performance as a single-pulse free-electron laser beam diagnostic was tested for two typical focusing configurations. The results derived from the speckle size/shape analysis show the effectiveness of this technique in fin...

متن کامل

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

The Linac Coherent Light Source Photo-Injector Overview and Some Design Details

The Linac Coherent Light Source (LCLS) is a SASE free electron laser using the last 1/3 of the SLAC two mile linac to produce 1.5 to 15 angstrom x-rays in a 100 meter long undulator for use in a variety of x-ray science experiments. In order to satisfy the demanding electron beam requirements, a new 135 MeV photo-injector will be built in an existing, off-axis vault at the 2/3 point of the main...

متن کامل

Chirped-beam two-stage free-electron laser for high-power femtosecond x-ray pulse generation

A method for generating femtosecond-duration x-ray pulses with a free-electron laser is presented. This method uses an energy-chirped electron beam propagating through an undulator to produce a frequencychirped x-ray pulse by self-amplified spontaneous emission. A short temporal pulse is created by use of a monochromator to select a narrow radiation bandwidth. A second undulator is used to ampl...

متن کامل

Linac Coherent Light Source Undulator Rf Bpm System *

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010