Septic transfusion case caused by a platelet pool with visible clotting due to contamination with Staphylococcus aureus.

نویسندگان

  • Maria Loza-Correa
  • Yuntong Kou
  • Mariam Taha
  • Miloslav Kalab
  • Jennifer Ronholm
  • Patrick M Schlievert
  • Michael P Cahill
  • Robert Skeate
  • Christine Cserti-Gazdewich
  • Sandra Ramirez-Arcos
چکیده

BACKGROUND Contamination of platelet concentrates (PCs) with Staphylococcus aureus is one of the most significant ongoing transfusion safety risks in developed countries. CASE REPORT This report describes a transfusion reaction in an elderly patient diagnosed with acute myeloid leukemia, transfused with a 4-day-old buffy coat PC through a central venous catheter. The transfusion was interrupted when a large fibrous clot in the PC obstructed infusion pump flow. Shortly afterward, a red blood cell (RBC) unit transfusion started. After septic symptoms were developed, the RBC transfusion was also interrupted. While the RBC unit tested negative for bacterial contamination, the PC and the patient samples were found to be contaminated with a S. aureus strain that exhibited the same phenotypic and genome sequencing profiles. The isolated S. aureus forms biofilms and produces the superantigen enterotoxin-like U, which was detected in a sample of the transfused PCs. The patient received posttransfusion antibiotic treatment and had her original central line removed and replaced. DISCUSSION As the implicated PC had been tested for bacterial contamination during routine screening yielding negative results, this is a false-negative transfusion sepsis case. Using a point-of-care test could have prevented the transfusion reaction. This report highlights the increasing incidence of S. aureus as a major PC contaminant with grave clinical implications. Importantly, S. aureus is able to interact with platelet components resulting in visible changes in PCs. CONCLUSION Visual inspection of blood components before transfusion is an essential safety practice to interdict the transfusion of bacterially contaminated units.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platelet Septic Transfusion Reactions in Patients With Hemato-Oncological Diseases

Background & Objective: Bacterial, contamination of blood components are a significant risk for transfusion reactions. Inherently, platelet concentrates (PCs) are vulnerable to bacterial contamination, due to the storage condition of processed PCs at room temperature, which provide very suitable conditions for the proliferation of microorganisms....

متن کامل

Comparison of Diagnostic Procedures for Platelet Products Contaminated with Strains of Staphylococcus Epidermidis and Klebsiella

Abstract Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration. Material and Methods: This laboratory ...

متن کامل

بررسی آلودگی نمونه‌های فرآورده پلاکت با باکتری‌های هوازی در مرکز انتقال خون اصفهان

Introduction: Although nowadays the risk of transmission of bacterial pathogens through blood transfusion has been decreased, but there is the possibility of transmission of these factors by injection of these kind of products. The purpose of this survey was determination of contamination of platelet products with aerobic bacteria in Isfahan Blood Transfusion Center. Methods: In the spring a...

متن کامل

Transfusion-transmitted bacterial infection as the source of Staphylococcus aureus bacteremia in patients with hematologic malignancies.

We read with great interest the paper by Venditti et al. about Staphylococcus aureus bacteremia (SAB) in patients with hematologic malignancies. We’d like to point out that SAB in hematologic patients could be the consequence of a bacterial contamination of transfused blood components, particularly when platelet transfusions are considered. This is because the platelet units are stored at room ...

متن کامل

گزارش یک مورد پلی آرتریت سپتیک ناشی از استافیلوکوکوس اورئوس

Staphylococcus aureus-induced septic polyarthritis is a rare entity characterized by the involvement of multiple joints. IV drug abusers are at increased risk, and it could be fatal if prompt intervention is delayed. Case report: A 30–year old male addict, (IV drug abuser), was admitted in Loghman hospital with high fever (38.5ºC), pulmonary symptoms, (cough and suppurative sputum), and pain a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transfusion

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2017