Comparison of cyclosporin G (Nva2-cyclosporin) concentrations measured in whole blood by monoclonal fluorescence polarization immunoassay, monoclonal radioimmunoassay, and HPLC.

نویسندگان

  • T M Annesley
  • R C Coombs
  • P J Orsulak
چکیده

Two commercial monoclonal immunoassays for monitoring cyclosporin A were used to measure whole-blood concentrations of the immunosuppressant cyclosporin G (CsG) in renal transplant patients. We performed a three-way comparison of these two immunoassays and HPLC. Although the two immunoassays agreed favorably, both the monoclonal fluorescence polarization immunoassay and the monoclonal RIA yielded higher CsG results for patients' specimens than did the liquid-chromatographic assay. The experimental data indicate that the observed differences are most likely due to the cross-reactivity of CsG metabolites in the immunoassays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady-state concentration of cyclosporin G (OG37-325) and its metabolites in renal transplant recipients.

The steady-state concentrations of cyclosporin G (OG37-325) (CsG) and six of its metabolites (GM1, GM9, GM4N, GM1c, GM1c9, GM19) were measured throughout the 12-h dosing interval in six renal transplant recipients receiving CsG as prophylaxis against acute cellular rejection. The mean 12-h whole-blood trough concentrations (micrograms/L) were CsG, 131 +/- 26; GM1, 79 +/- 55; GM9, 110 +/- 114; G...

متن کامل

A validation study of selected methods routinely used for measurement of cyclosporine.

We compare four methods for measuring cyclosporine (CyA) in plasma and whole blood of transplant patients: HPLC, RIA with a polyclonal antibody, RIA with a monoclonal antibody, and fluorescence polarization immunoassay (FPIA). The monoclonal RIA procedure correlated acceptably with HPLC, with slope = 1.21, r = 0.97, and Sy,x = +/- 40.1. However, the FPIA, done in three separate instruments, cor...

متن کامل

Whole-blood cyclosporin G in renal transplant recipients determined by two immunoassays and liquid chromatography.

Cyclosporin G (CsG) is less nephrotoxic than cyclosporin A (CsA) and is undergoing clinical trials for use as an immunosuppressive agent after renal transplantation. Three assays for whole-blood CsA-HPLC, RIA (INCSTAR, Cyclo-Trac SP), and FPIA (Abbott TDx)--were adapted for use with CsG and were assessed for analytical suitability and to determine which assay was capable of deriving CsG values ...

متن کامل

Chemiluminescence immunoassay of cyclosporine in whole blood.

We describe a chemiluminescent immunoassay (CLI) for measuring cyclosporine in whole blood. Its sensitivity and accuracy are comparable with those of an RIA method that makes use of the same specific monoclonal antibody. The comparison with the RIA method was excellent: y(RIA) = x(CLI) + 11.24 (r = 0.99). In our procedure the samples are incubated with cyclosporin C-hemisuccinate-aminobutyl-N-e...

متن کامل

CYP3A5 genotype does not influence the blood concentration of tacrolimus measured with the Abbott immunoassay.

To the Editor: Therapeutic drug monitoring of immunosuppressants is well established as an aid to optimizing patient management after allograft transplantation. Most laboratories measure cyclosporin and tacrolimus by immunoassays. However, measured values may be affected by the presence of circulating metabolites because of the limited specificity of the antibodies used in these assays. Cyclosp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 1993