Image Quality of Digital Direct Flat-Panel Mammography Versus an Indirect Small-Field CCD Technique Using a High-Contrast Phantom
نویسندگان
چکیده
OBJECTIVE To compare the detection of microcalcifications on mammograms of an anthropomorphic breast phantom acquired by a direct digital flat-panel detector mammography system (FPM) versus a stereotactic breast biopsy system utilizing CCD (charge-coupled device) technology with either a 1024 or 512 acquisition matrix (1024 CCD and 512 CCD). MATERIALS AND METHODS Randomly distributed silica beads (diameter 100-1400 μm) and anthropomorphic scatter bodies were applied to 48 transparent films. The test specimens were radiographed on a direct digital FPM and by the indirect 1024 CCD and 512 CCD techniques. Four radiologists rated the monitor-displayed images independently of each other in random order. RESULTS The rate of correct positive readings for the "number of detectable microcalcifications" for silica beads of 100-199 μm in diameter was 54.2%, 50.0% and 45.8% by FPM, 1024 CCD and 512 CCD, respectively. The inter-rater variability was most pronounced for silica beads of 100-199 μm in diameter. The greatest agreement with the gold standard was observed for beads >400 μm in diameter across all methods. CONCLUSION Stereotactic spot images taken by 1024 matrix CCD technique are diagnostically equivalent to direct digital flat-panel mammograms for visualizing simulated microcalcifications >400 μm in diameter.
منابع مشابه
ارزیابی میزان دقت جداسازی تصاویر دو ماده حاجب مختلف به صورت همزمان از بافت پستان با استفاده از تکنیک ماموگرافی دیجیتال دو انرژی
Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. Materials and methods: A breast phantom was designed and b...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملImage quality of digital direct flat-panel mammography versus an analog screen-film technique using a phantom model.
OBJECTIVE The objective of our study was to compare the detection and distinguishability of microcalcifications on mammograms obtained with a digital direct flat-panel detector versus an analog system using an anthropomorphic breast phantom. MATERIALS AND METHODS Studies were performed with a digital mammography system (Selenia) and an analog mammography system (Mammomat 3). Sixty-five transp...
متن کاملبررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان
Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accura...
متن کاملA New Method for Dosimetry and Image Quality Assurance
Introduction and purpose: The latest developments in breast imaging technology have underlined the need for appropriate dosimetry and image evaluation methods for routine quality assurance. We are presenting QUART evaluation method (phantom and dosimeter) to address this need for digital x-ray mammography and breast tomosynthesis systems. We compare our dose measurements to the dose readings fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2011 شماره
صفحات -
تاریخ انتشار 2011