Stationary-Frame Modeling of VSC Based on Current-Balancing Driven Internal Voltage Motion for Current Control Timescale Dynamic Analysis

نویسندگان

  • Yabing Yan
  • Xiaoming Yuan
  • Jiabing Hu
چکیده

High-frequency oscillations caused by voltage source converters (VSCs) are constantly emerging in power systems with the increasing penetration of renewable energies. VSC models in current control timescale play a pivotal role in the analysis of these oscillation issues. Conventional VSC models show few physical mechanisms of VSC dynamics during system oscillations. Hence, this paper proposes a VSC model from the viewpoint of its internal voltage (namely, VSC output voltage), which is driven by current balancing between the current reference and the feedback in a stationary frame. The proposed model can be used to study VSC dynamic characteristics in an intuitionistic physical way. Based on the proposed model, it is found that VSC current reference in a stationary frame varies with internal voltage dynamic due to the essence of active and reactive current control in a current control timescale. Additionally, in a stationary frame, the dynamic relation between internal voltage and error current embodies a generalized integrating characteristic with adaptable center frequency determined by a phase-locked loop, which guarantees the zero steady state error of VSC current control. Comparisons of simulations between the proposed model and a switch-based model validates the effectiveness of the proposed model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of the Min-Projection and the Model Predictive Strategies for Current Control of Three-Phase Grid-Connected Converters: a Comparative Study

This paper provides a detailed comparative study concerning the performance of min-projection strategy (MPS) and model predictive control (MPC) systems to control the three-phase grid connected converters. To do so, first, the converter is modeled as a switched linear system. Then, the feasibility of the MPS technique is investigated and its stability criterion is derived as a lower limit on th...

متن کامل

Dynamic Performance Analysis of High-Frequency Signal Injection Based Sensorless Methods for Interior Permanent Magnet Synchronous Motors

This paper focuses on three commonly used sensorless methods based on high-frequency signal injection; namely, the rotating sinusoidal injection in the stationary reference frame, the pulsating sinusoidal injection in the estimated synchronous reference frame, and the pulsating square wave injection in the estimated synchronous reference frame. Although these methods have found applications in ...

متن کامل

Modeling, Simulation and Control of Matrix Convert for Variable Speed Wind Turbine System

This paper presents modeling, simulation and control of matrix converter (MC) for variable speed wind turbine (VSWT) system including permanent magnet synchronous generator (PMSG). At a given wind velocity, the power available from a wind turbine is a function of its shaft speed. In order to track maximum power, the MC adjusts the PMSG shaft speed.The proposed control system allowing independen...

متن کامل

Dynamic Harmonic Modeling and Analysis of VSC-HVDC Systems

Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...

متن کامل

Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition

This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018