Non-invasive quantification of physiological processes with dynamic PET using blind deconvolution
نویسندگان
چکیده
Dynamic Positron Emission Tomography (PET) has opened the possibility of quantifying physiological processes within the human body. On performing dynamic PET studies, the tracer concentration in blood plasma has to be measured, and acts as the input function for tracer kinetic modelling. In this paper, we propose an approach to estimate physiological parameters for dynamic PET studies without the need of taking blood samples. The proposed approach comprises two major steps. First, a wavelet denoising technique is used to filter the noise appeared in the projections. The denoised projections are then used to reconstruct the dynamic images using filtered backprojection. Second, an eigen-vector based blind deconvolution technique is applied to the reconstructed dynamic images to estimate the physiological parameters. To demonstrate the performance of the proposed approach, we carried out a Monte Carlo simulation using the fluoro-deoxy-2glucose model, as applied to tomographic studies of human brain. The results demonstrate that the proposed approach can estimate the physiological parameters with an accuracy comparable to that of invasive approach which requires the tracer concentration in plasma to be measured.
منابع مشابه
Improved quantification of salivary gland scintigraphy by means of factor analysis
Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...
متن کاملEstimation of input function from dynamic PET brain data using Bayesian blind source separation
Selection of regions of interest in an image sequence is a typical prerequisite step for estimation of time-activity curves in dynamic positron emission tomography (PET). This procedure is done manually by a human operator and therefore suffers from subjective errors. Another such problem is to estimate the input function. It can be measured from arterial blood or it can be searched for a vascu...
متن کاملBlind Deconvolution of PET Images using Anatomical Priors
Images from positron emission tomography (PET) provide metabolic information about the human body. They present, however, a spatial resolution that is limited by physical and instrumental factors often modeled by a blurring function. Since this function is typically unknown, blind deconvolution (BD) techniques are needed in order to produce a useful restored PET image. In this work, we propose ...
متن کاملNon-Invasive estimation of Cerebral Metabolic Rate of Glucose Using Simultaneous Estimation and Cluster Analysis: A feasibility Study
Quantitative PET studies usually require invasive blood sampling from a peripheral artery to obtain an input function for accurate modelling. However, blood sampling is impractical in clinical PET studies. We recently proposed a non-invasive modelling approach that can simultaneously estimate parameters which describe both the input and output functions using two or more regions of interest (RO...
متن کاملFixed Vs Adaptable Point Spread Function (psf) in Deconvolution Two-photon Microscopy of Pathological Neo-vasculature
Pathological neo-vascularization, i.e., the expansion of the vascular bed in solid tumors and after hindlimb ischemia and myocardial infarction, occurs through angiogenesis and/or arteriogenesis [1]. Quantification of microvascular morphology would allow evaluation of the effect of proand anti-angiogenic therapy. However, due to the point spread function (PSF) of the TPLSM setup, quantification...
متن کامل