Dried blood spots perform well in viral load monitoring of patients who receive antiretroviral treatment in rural Tanzania.

نویسندگان

  • Asgeir Johannessen
  • Carolina Garrido
  • Natalia Zahonero
  • Leiv Sandvik
  • Ezra Naman
  • Sokoine L Kivuyo
  • Mabula J Kasubi
  • Svein G Gundersen
  • Johan N Bruun
  • Carmen de Mendoza
چکیده

BACKGROUND Monitoring of antiretroviral treatment (ART) with human immunodeficiency virus (HIV) viral loads, as recommended in industrialized countries, is rarely available in resource-limited settings because of the high costs and stringent requirements for storage and transport of plasma. Dried blood spots (DBS) can be an alternative to plasma, but the use of DBS has not been assessed under field conditions in rural Africa. The present study investigates the performance of DBS in HIV viral load monitoring of patients who received ART in rural Tanzania. PATIENTS AND METHODS From November 2007 through June 2008, parallel plasma and DBS specimens were obtained from patients who received ART at Haydom Lutheran Hospital in rural Tanzania. DBS specimens were stored at tropical room temperature for 3 weeks before testing with the NucliSENS EasyQ HIV-1 v1.2 assay. Results obtained with DBS were compared with results obtained with use of a gold-standard plasma assay. RESULTS Ninety-eight plasma-DBS pairs were compared, and plasma viral loads ranged from <40 to >1,000,000 copies/mL. The correlation between plasma and DBS viral load was strong (R(2) = 0.75). The mean difference (+/- standard deviation) was 0.04 +/ 0.57 log(10) copies/mL, and only 8 samples showed >1 log(10) copies/mL difference. HIV type 1 RNA was detected in 7%, 60%, and 100% of DBS specimens with corresponding plasma viral loads of 40-999, 1000-2999, and 3000 copies/mL, respectively. CONCLUSIONS DBS, in combination with the NucliSENS EasyQ HIV-1 v1.2 asay, performed well in monitoring HIV viral loads in patients who received ART in rural Tanzania, although the sensitivity was reduced when viral burden was low. The use of DBS can simplify virological monitoring in resource-limited settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIV-1 drug resistance testing from dried blood spots collected in rural Tanzania using the ViroSeq HIV-1 Genotyping System

OBJECTIVES To assess whether the commercial ViroSeq HIV-1 Genotyping System (Abbott Molecular, Des Plains, IL, USA) can be used in conjunction with dried blood spots (DBS) for clinical monitoring of drug resistance in patients who fail antiretroviral treatment (ART) in rural Tanzania. PATIENTS AND METHODS Patients at Haydom Lutheran Hospital with confirmed treatment failure (viral load >1000 ...

متن کامل

Pooling strategies to reduce the cost of HIV-1 RNA load monitoring in a resource-limited setting.

BACKGROUND Quantitative human immunodeficiency virus (HIV) RNA load testing surpasses CD4 cell count and clinical monitoring in detecting antiretroviral therapy (ART) failure; however, its cost can be prohibitive. Recently, the use of pooling strategies with a clinically appropriate viral load threshold was shown to be accurate and efficient for monitoring when the prevalence of virologic failu...

متن کامل

Dried blood spots can expand access to virological monitoring of HIV treatment in resource-limited settings.

The global scale-up of antiretroviral treatment in past years has, unfortunately, not been accompanied by adequate strengthening of laboratory capacity. Monitoring of treatment with HIV viral load and resistance testing, as recommended in industrialized countries, is rarely available in resource-limited settings due to high costs and stringent requirements for storage and transport of plasma. C...

متن کامل

Pyrosequencing Dried Blood Spots Reveals Differences in HIV Drug Resistance between Treatment Naïve and Experienced Patients

Dried blood spots (DBS) are an alternative specimen collection format for HIV-1 genotyping. DBS produce HIV genotyping results that are robust and equivalent to plasma when using conventional sequencing methods. However, using tagged, pooled pyrosequencing, we demonstrate that concordance between plasma and DBS is not absolute and varies according to viral load (VL), duration of HIV infection a...

متن کامل

Pooled HIV-1 Viral Load Testing Using Dried Blood Spots to Reduce the Cost of Monitoring Antiretroviral Treatment in a Resource-Limited Setting

Rollout of routine HIV-1 viral load monitoring is hampered by high costs and logistical difficulties associated with sample collection and transport. New strategies are needed to overcome these constraints. Dried blood spots from finger pricks have been shown to be more practical than the use of plasma specimens, and pooling strategies using plasma specimens have been demonstrated to be an effi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical infectious diseases : an official publication of the Infectious Diseases Society of America

دوره 49 6  شماره 

صفحات  -

تاریخ انتشار 2009