Precision measurement of transition matrix elements via light shift cancellation.
نویسندگان
چکیده
We present a method for accurate determination of atomic transition matrix elements at the 10(-3) level. Measurements of the ac Stark (light) shift around "magic-zero" wavelengths, where the light shift vanishes, provide precise constraints on the matrix elements. We make the first measurement of the 5s - 6p matrix elements in rubidium by measuring the light shift around the 421 and 423 nm zeros through diffraction of a condensate off a sequence of standing wave pulses. In conjunction with existing theoretical and experimental data, we find 0.3235(9)ea(0) and 0.5230(8)ea(0) for the 5s - 6p(1/2) and 5s - 6p(3/2) elements, respectively, an order of magnitude more accurate than the best theoretical values. This technique can provide needed, accurate matrix elements for many atoms, including those used in atomic clocks, tests of fundamental symmetries, and quantum information.
منابع مشابه
Differential light-shift cancellation in a magnetic-field-insensitive transition of 87rb.
The precise measurement of transition frequencies of trapped atomic samples is susceptible to inaccuracy arising from the inhomogeneous differential shift of the relevant energy levels in the presence of the trapping fields. We demonstrate near-complete cancellation of the differential ac Stark shift ("light shift") of a two-photon magnetic-field-insensitive microwave hyperfine (clock) transiti...
متن کاملTowards Measurement of Polarization Properties of Skin using the Ellipsometry Technique
Introduction: The human skin is an active medium from the optical point of view. Therefore, the diagnostic and therapeutic techniques employing light are increasing. Current optical techniques are based on the measurement of the intensity of reflected absorbed or backscattered light from or within skin. Studies have shown that biological tissues, and in particular skin, demonstrate polarization...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملar X iv : p hy si cs / 0 50 21 13 v 1 2 2 Fe b 20 05 Precision measurement of light shifts in a single trapped Ba + ion
Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the 6S1/2 and 5D3/2 states to 0.1% precision. We find R ≡ ∆S/∆D = −11.494(13) at 514.531 nm where ∆S,D are the light shifts of the m = ±1/2 splittings due to circularly polarized light. Comparison of this result with an ab initio ca...
متن کاملUsing tensor light shifts to measure and cancel a cell’s quadrupolar frequency shift
We have developed a technique that uses the tensor light shift to measure and cancel the frequency shift produced by the quadrupolar anisotropy of a vapor cell. We demonstrate the technique on the 6S1/2, F = 4 level of Cs using the D1 transition. The method extends our ability to study quadrupolar wall interactions beyond diamagnetic atoms. We have deduced the twist angle per wall adhesion for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 109 24 شماره
صفحات -
تاریخ انتشار 2012