First experience in Italy with a new transcutaneous bone conduction implant
نویسندگان
چکیده
Since 2011, transcutaneous bone-anchored auditory implants have been an alternative to the classic percutaneous implant (Baha) for bilateral conductive/mixed hearing loss that cannot be corrected by surgery. Recently, a new transcutaneous device has been approved for clinical use. Its internal component is made of the classic titanium Baha fixture, coupled to a 27 mm diameter subcutaneous circular magnet. The external component includes a second circular magnet 29 mm in diameter and a digital sound processor. To date, there are no reports describing the results of the application of this device. The aim of the present study is to report on the anatomical and functional results of transcutaneous Baha implantation in three patients: two adults, one with syndromic aural atresia and one with bilateral conductive hearing loss due to bilateral tympanomastoidectomy, and an 8-year-old child with non-syndromic aural atresia. No major intraoperative or postoperative complications were observed. The three patients tolerated the external magnet, with no signs of skin irritation. Functional results were good: median unaided free-field PTA (0.5-3 kHz) was 50 dB HL (range = 41-66 dB HL); with the transcutaneous Baha median PTA (0.5-3 kHz) was 27 dB HL (range = 25-30 dB HL) and median gain was 25 dB HL (range = 11-39 dB HL). Preliminary results encourage use of the device as a valuable alternative to other implantable devices in these patients. To ensure the success of treatment, several precautions are suggested including gradually increasing use during the first post-operative months to favour skin adaptation to magnet pressure. In addition to skin reactions, in a paediatric age most concerns are related to the curvature of the skull, which may induce tenting of the skin over the internal magnet.
منابع مشابه
Adipose- Derived Stem Cells as a Tool for Dental Implant Osseointegration: an Experimental Study in the Dog
The biological interaction between the jaw bones and dental implant is fundamental for the long-term success of dental implant placement. Nevertheless, the insufficient bone volume remains a major clinical problem, especially in case of immediate dental implant. Using a canine model, the present study proves the regenerative potential of adipose- derived stem cells (ADSCs) to repair peri-implan...
متن کاملNew closed skin bone-anchored implant: preliminary results in 6 children with ear atresia.
OBJECTIVE To report preliminary results of a new closed-skin, transcutaneous bone conduction device (BCD) in 6 children with high-grade ear atresia. SETTINGS Tertiary care center; prospective study; we evaluated the gain with masking of the contralateral ear and the benefit of hearing rehabilitation with the transcutaneous BCD in noise: speech-in-noise tests, conducted in real life condition ...
متن کاملNew developments in bone-conduction hearing implants: a review
The different kinds of bone-conduction devices (BCDs) available for hearing rehabilitation are growing. In this paper, all BCDs currently available or in clinical trials will be described in categories according to their principles. BCDs that vibrate the bone via the skin are referred to as skin-drive devices, and are divided into conventional devices, which are attached with softbands, for exa...
متن کاملBreakthroughs in Bone Conduction Hearing Implants HOW INDUSTRY-LEADING INNOVATION HAS TRANSFORMED CLINICAL AND PATIENT EXPERIENCES
The introduction of the CochlearTM Baha® BI300 Implant and DermaLockTM Abutment (BA400) have significantly improved clinical practices and the patient experience with bone conduction hearing implants. First introduced in 2010, the BI300 Implant is now used by over 50,000 patients worldwide. Of these patients, more than 24,000 have also received the DermaLock Abutment since its introduction in 2...
متن کاملThe bone conduction implant: Clinical results of the first six patients
OBJECTIVE To investigate audiological and quality of life outcomes for a new active transcutaneous device, called the bone conduction implant (BCI), where the transducer is implanted under intact skin. DESIGN A clinical study with sound field audiometry and questionnaires at six-month follow-up was conducted with a bone-anchored hearing aid on a softband as reference device. STUDY SAMPLE Si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 35 شماره
صفحات -