Non-CPMG Fast Spin Echo with full signal.

نویسنده

  • Patrick Le Roux
چکیده

The standard Fast Spin Echo sequence used in MR imaging relies on the CPMG condition. A consequence of this condition is that only one component of the transverse magnetization can be measured. To counter this, some phase modulation schemes (XY, MLEV.) for the pulse train have been proposed, but they are useful only over a very restricted range, close to pi, of the refocusing pulse rotation angle. Some other solutions not relying on phase modulation have also been suggested, but they destroy one half the available signal. Revisiting the phase modulation approach, J. Murdoch ("Second SMR Scientific Meeting," p. 1145, 1994) suggested that a quadratic phase modulation could generate a train of classical echoes. We show here that indeed a quadratic phase modulation has a very suitable property: after an adequate change of frame, the dynamic of the system composed of all the protons situated in one pixel can be seen as stationary. If the parameter of the quadratic phase modulation is well chosen, it is then possible to put the dynamic system in a combination of two suitable states and obtain a signal identical to the signal of a classical spin echo, at least for nutation of the refocusing pulse higher than, approximately, two radians.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion tensor imaging of the human optic nerve using a non-CPMG fast spin echo sequence.

PURPOSE To investigate the diffusion tensor properties of the human optic nerve in vivo using a non-Carr-Purcell-Meiboom-Gill (CPMG) fast spin echo (FSE) sequence. MATERIALS AND METHODS This non-CPMG FSE sequence, which is based on a quadratic phase modulation of the refocusing pulses, allows diffusion measures to be acquired with full signal and without artifacts from geometric distortions d...

متن کامل

Turbo Spin Echo Bloch Siegert Shift B1 Mapping

An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...

متن کامل

Accelerated acquisition and reconstruction of non-CPMG fast spin echo sequences

Introduction: Quadratic phase modulation of the refocusing pulses in a fast spin echo (FSE) sequence [1,2] has been shown to sustain signal magnitude and phase regardless of the signal phase at the beginning of the echo train. This technique, also known as non-CPMG (Carr-Purcell-Meiboom-Gill) FSE, generates two sets of signals in a single echotrain, which typically are saved and reconstructed s...

متن کامل

Multiplex RARE Dixon: a novel multislice RARE sequence applied to simultaneous slice fat-water Dixon imaging

Introduction Multislice excitation methods have been widely used to increase efficiency in volume coverage. In the simultaneous spin-echo refocusing sequence (SER) [1], two or more slices are excited simultaneously and refocused with a train of 180° pulses which act simultaneously on both slices. However, the SER sequence does not fulfil CPMG conditions, and requires special spoiler gradients t...

متن کامل

Diffusion-weighted imaging of the spine with a non-carr-purcell-meiboom-gill single-shot fast spin-echo sequence: initial experience.

BACKGROUND AND PURPOSE To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS Twenty-four patients were enrolled after w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 155 2  شماره 

صفحات  -

تاریخ انتشار 2002