An indirect transmission measurement-based spectrum estimation method for computed tomography.

نویسندگان

  • Wei Zhao
  • Kai Niu
  • Sebastian Schafer
  • Kevin Royalty
چکیده

The characteristics of an x-ray spectrum can greatly influence imaging and related tasks. In practice, due to the pile-up effect of the detector, it's difficult to directly measure the spectrum of a CT scanner using an energy resolved detector. An alternative solution is to estimate the spectrum using transmission measurements with a step phantom or another CT phantom. In this work, we present a new spectrum estimation method based on indirect transmission measurement and a model spectra mixture approach. The estimated x-ray spectrum was expressed as a weighted summation of a set of model spectra, which can significantly reduce the degrees of freedom of the spectrum estimation problem. Next, an estimated projection was calculated with the assumed spectrum. By iteratively updating the unknown weights, we minimized the difference between the estimated projection data and the raw projection data. The final spectrum was calculated with these calibrated weights and the model spectra. Both simulation and experimental data were used to evaluate the proposed method. In the simulation study, the estimated spectra were compared to the raw spectra which were used to generate the raw projection data. For the experimental study, the ground truth measurement of the raw x-ray spectrum was not available. Therefore, the estimated spectrum was compared against the spectra generated using the SpekCalc software with tube configurations provided by the scanner manufacturer. The results show the proposed method has the potential to accurately estimate x-ray spectra using the raw projection data. The difference between the mean energy of the raw spectra and the mean energy of the estimated spectra was less than 0.5 keV for both the simulation and experimental data. Further tests show the method was robust with respect to the model spectra generator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

An Advanced State Estimation Method Using Virtual Meters

-  Power system state estimation is a central component in energy management systems of power system. The goal of state estimation is to determine the system status and power flow of transmission lines. This paper presents an advanced state estimation algorithm based on weighted least square (WLS) criteria by introducing virtual meters. For each bus of network, except slack bus, a virtual meter...

متن کامل

Determination of height of urban buildings based on non-parametric estimation of signal spectrum in SAR data tomography

Nowadays, the TomoSAR technique has been able to overcome the limitations of radar interferometry techniques in separating multiple scatterers of pixels. By extending the principles of virtual aperture in the elevation direction, these techniques pay much attention in the analysis of urban challenging areas. Despite the expectation of interference of the distribution of buildings with different...

متن کامل

An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements.

PURPOSE Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2015