Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation

نویسندگان

  • Zhuyu Wang
  • Wen Zhang
  • Xiaolei Zhang
چکیده

OBJECTIVES To evaluate the cyclic fatigue resistance and the force generated by OneShape files during preparation of simulated curved canals. METHODS Six OneShape files (the test) and six ProTaper F2 files (the control) were subject to the bending ability test. Another thirty files of each type were used to prepare artificial canals (n = 60), which were divided into 3 groups according to respective curvatures of the canals (30°, 60°, and 90°). The numbers of cycles to fatigue (NCF) as well as the positive and negative forces that were generated by files during canal preparation were recorded. The scanning electron microscopy was applied to detect the fracture surfaces. RESULTS Compared with ProTaper F2 files, the bending loads of OneShape files were significantly lower at deflections of 45°(P < .05), 60° (P < .05) and 75° (P < .01). No significant difference was found at 30°. OneShape files presented a higher NCF in both 60° and 90° canals than the control (P < .01). No significant difference of NCF was found between OneShape and ProTaper files in 30° canals. During the preparation of 30° canals by both files, the negative forces were dominant. With the increase of the curvature, more positive forces were observed. When the OneShape Files were compared with the control, significant different forces were found at D3 and D2 (P < .05) in 30° canals, at D2 (P < .05), D1 (P < .01) and D0 (P < .01) in 60° canals, and at D4 and D3 (P < .01) in 90° canals. CONCLUSIONS OneShape files possessed a reliable flexibility and cyclic fatigue resistance. According to the assessments of the forces generated by files, OneShape instruments performed in a more fatigue-resistant way during curved canal preparation, compared with the ProTaper F2 files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments.

AIM To compare the cyclic fatigue resistance of new generation OneShape and WaveOne instruments when used with different kinematics. METHODOLOGY An artificial canal, made of stainless steel with an inner diameter of 1.5 mm, a 60° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of new generation OneShape and WaveOne instruments. Groups were as follows (n = 2...

متن کامل

Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.

The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived fro...

متن کامل

Cyclic fatigue resistance of OneShape and WaveOne instruments using different angles of curvature.

This study compared the cyclic fatigue resistance of OneShape (OS) instrument which used continuous rotation with WaveOne (WO) instrument which used reciprocating motion. OS size 25, 0.06 taper and WO primary size 25, 0.08 taper were used in simulated canals with 45°, 60°, and 90° angles of curvature until fracture. The number of cycles to fracture (NCF) was recorded to evaluate cyclic fatigue ...

متن کامل

Cyclic fatigue of Reciproc and WaveOne reciprocating instruments.

AIM To evaluate the cyclic fatigue resistance of Reciproc(®) and WaveOne(®) instruments in simulated root canals. METHODOLOGY Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc(®) R25 and group B: WaveOne(®) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instrument's ...

متن کامل

Cyclic fatigue resistance of rotary NiTi instruments after simulated clinical use in curved root canals.

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016